Cloud Monitoring

Performance Analysis

Performance Analysis displays the performance metrics of key resources monitored externally or internally in the Cloud. You can view the performance analysis or export the analysis report as needed to improve the O&M efficiency.

View Performance Analysis

On the main menu of ZStack Cube Ultimate, choose Platform O&M > Cloud Monitoring > Monitoring Chart > Performance Analysis. Then, the Performance Analysis page is displayed.

Figure 1. View Performance Analysis


The Performance Analysis page consists of filters and analysis reports.
  • Filters: Supports basic filtering and advanced filtering.
    • Basic filtering: Allows you to filter by resource, monitoring methods, and time spans.
      • Resource: Supports VM instances, VPC vRouters, hosts, backup storages, L3 networks, and virtual IPs.
      • Monitoring method: Supports external monitoring and internal monitoring.
        • External monitoring: Obtains the VM performance data, such as the CPU, memory, disk I/O, and NIC data from the host by using libvirt.
        • Internal monitoring: Obtains the VM performance data, such as the CPU, memory, and disk capacity directly by using the agent and pushes the data to the host. To using internal monitoring, install the agent first.
        Note: The memory data obtained by using internal monitoring is more accurate than that obtained by external monitoring. Therefore, we recommend that you use internal monitoring to monitor the memory data.
      • Time span: You can select a time span to view the monitoring data. Available time spans: 15 minutes, 1 hour, 1 week, and custom.
    • Advanced filtering: Allows you to further filter by filter item, resource scope, and owner scope.
      • Filter item: Allows you to sort and view resources based on monitoring metrics and metric values (for example, CPU utilization >= 75%).
      • Resource range: Allows you to view the monitoring information of all resources on the Cloud or specify a resource to view its own monitoring information.
      • Owner range: Allows you to view the monitoring information of all owners in the Cloud or specify an owner to view the monitoring information.
  • Analysis report: Generates an analysis report based on the filter conditions.
    • Allows you to sort the items by resource name or monitoring metric.
    • Allows you to export all the report information or export the information on the current page in CSV format.
    • Allows you to customize the number of items to be displayed on each page. By default, 10 items are displayed per page.
    Note:
    • The VM analysis report page allows you to stop a VM instance.
    • The VM analysis report page allows you to filter VM instances based on the VM state.
    • The VM/VPC vRouter analysis report allows you to customize the columns to be displayed.
    • When you export a VM or VPC vRouter analysis report, you can choose to export the average, maximum, or minimum values of the metrics as needed.
The following table lists the monitoring metrics of each resources.
Resource Type Monitoring Method Monitoring Metric Destription
VM Instance/VPC vRouter External Monitoring Default IPv4 Displays the default IPv4 address of each VM instance in the current zone by default.
Note: This metric does not apply to VPC vRouters currently.
Volume Actual Size Displays the volume actual size of each VM instance in the current zone by default.
Note: This metric does not apply to VPC vRouters currently.
Total Volume Capacity Displays the total volume capacity of each VM instance in the current zone by default.
Note: This metric does not apply to VPC vRouters currently.
CPU Utilization Displays the average CPU utilization of all the VM instances/VPC vRouters in the current zone by default.
Note: If a VM instance or VPC vRouter has more than one CPU, the CPU utilization might be greater than 100%.
Memory Utilization Displays the average memory utilization of all the VM instances/VPC vRouters in the current zone by default.
Disk Read Rate Displays the average disk read speed of all the VM instances/VPC vRouters in the current zone by default.
Disk Write Rate Displays the average disk write speed of all the VM instances/VPC vRouters in the current zone by default.
NIC In Rate Displays the average NIC in rate of all the VM instances/VPC vRouters in the current zone by default.
NIC Out Rate Displays the average NIC out rate of all the VM instances/VPC vRouters in the current zone by default.
Disk Read IOPS Displays the average disk read IOPS of all the VM instances/VPC vRouters in the current zone by default.
Disk Write IOPS Displays the average disk write IOPS of all the VM instances/VPC vRouters in the current zone by default.
NIC In Packets Displays the average number of received NIC packets of all the VM instances/VPC vRouters in the current zone by default.
NIC Out Packets Displays the average number of sent NIC packets of all the VM instances/VPC vRouters in the current zone by default.
NIC In Errors Rate Displays the average rate of received NIC errors of all the VM instances/VPC vRouters in the current zone by default.
NIC Out Errors Rate Displays the average rate of sent NIC errors of all the VM instances/VPC vRouters in the current zone by default.
Internal Monitoring Default IPv4 Displays the default IPv4 address of each VM instance in the current zone by default.
Note: This metric does not apply to VPC vRouters currently.
Volume Actual Size Displays the volume actual size of each VM instance in the current zone by default.
Note: This metric does not apply to VPC vRouters currently.
Volume Actual Size Displays the volume actual size of each VM instance in the current zone by default.
Note: This metric does not apply to VPC vRouters currently.
CPU Utilization Displays the average CPU utilization of all the VM instances/VPC vRouters in the current zone by default.
CPU Occupancy Rate (System Process) Displays the average CPU occupancy rate (system process) of all the VM instances/VPC vRouters in the current zone by default.
CPU Occupancy Rate (User Process) Displays the average CPU occupancy rate (user process) of all the VM instances/VPC vRouters in the current zone by default.
CPU Occupancy Rate (Waiting) Displays the average CPU occupancy rate (waiting) of all the VM instances/VPC vRouters in the current zone by default.
CPU Idle Rate Displays the average CPU idle rate of all the VM instances/VPC vRouters in the current zone by default.
Memory Utilization Displays the average memory utilization of all the VM instances/VPC vRouters in the current zone by default.
Memory Idle Rate Displays the average memory idle rate of all the VM instances/VPC vRouters in the current zone by default.
Disk Utilization Displays the average disk utilization of all the VM instances/VPC vRouters in the current zone by default.
Disk Idle Rate Displays the average disk idle rate of all the VM instances/VPC vRouters in the current zone by default.
Host / Disk Read IOPS Displays the disk read IOPS of all the hosts in the current zone by default.
/ Disk Write IOPS SDisplays the write read IOPS of all the hosts in the current zone by default.
/ Used Disk Storage Percentage Displays the used disk storage percentage of all the hosts in the current zone by default.
/ Disk Usage Displays the disk usage of all the hosts in the current zone by default.
/ NIC In Rate Displays the NIC in rate of all the hosts in the current zone by default.
/ NIC Out Rate Displays the NIC out rate of all the hosts in the current zone by default.
/ NIC In Errors Rate Displays the NIC in erros rate of all the hosts in the current zone by default.
/ NIC Out Errors Rate Displays the NIC out errors rate of all the hosts in the current zone by default.
/ CPU Utilization Average Displays the average CPU utilization of all the hosts in the current zone by default.
/ Memory Utilization Displays the memory utilization of all the hosts in the current zone by default.
/ Disk Read Speed Displays the disk read speed of all the hosts in the current zone by default.
/ Disk Write Speed Displays the disk write speed of all the hosts in the current zone by default.
/ NIC In Speed Displays the NIC in speed of all the hosts in the current zone by default.
/ NIC Out Speed Displays the NIC out speed of all the hosts in the current zone by default.
Backup Storage / Backup Storage Capacity Available Percent Displays the percentage of available capacity of all the backup storages in the current zone by default.
L3 Network / Used IPs (IPv4) Displays the number of used IPv4 IPs of all L3 networks in the current zone by default.
/ Used IP Percentage (IPv4) Displays the percentage of used IPv4 IPs of all L3 networks in the current zone by default.
/ Available IPs (IPv4) Displays the number of available IPv4 IPs of all L3 networks in the current zone by default.
/ Available IP Percentage (IPv4) Displays the percentage of available IPv4 IPs of all L3 networks in the current zone by default.
Virtual IP / Inbound Traffic Displays the inbound traffic of all virtual IP addresses in the current zone by default.
/ Inbound Traffic Rate Displays the inbound traffic rate of all virtual IP addresses in the current zone by default.
/ Outbound Traffic Displays the outbound traffic of all virtual IP addresses in the current zone by default.
/ Outbound Traffic Rate Displays the outbound traffic rate of all virtual IP addresses in the current zone by default.

Export Analysis Report

You can export all the analysis information of a resource or only information on the current page based on the filter conditions. For VM instance and VPC vRouters, you can customize the monitoring metrics to be exported and choose to export their average values, maximum values, or minimum values as needed.

On the main menu of ZStack Cube Ultimate, choose Platform O&M > Cloud Monitoring > Monitoring Chart > Performance Analysis. Then, the Performance Analysis page is displayed. Taking VM instance as an example, on the analysis report area, click Export CSV and choose Current Page or All. Then, the export page is displayed.

Figure 2. Export Analysis Information on the Current Page


  • The export page displays the selected resource, monitoring method, time span, and all the monitoring metrics of the resource.
  • By default, metrics displayed in the VM/VPC vRouter list are automatically selected. You can deselect them or select the average, maximum, or minimum value of other metrics.
  • You can select all the average, maximum, and minimum values or empty your selections with one click.

Management Node Monitoring

Management Node (MN) monitoring allows you to view the health status of each management node when you use multiple management nodes to achieve high availability.

Monitoring and Alarm

The Monitoring and Alarm feature monitors time-series data and events and sends alarm messages to specified endpoints by using SNS. Resource alarms, event alarms, and extended alarms are supported. The supported endpoints include the system, emails, DingTalk, HTTP applications, text messages, and Microsoft Teams. For some resource alarms, you need to install the agent before they can work as expected.

Concepts

  • Monitoring System:
    A monitoring system provides the following features:
    • Monitor the following two types of time-series data:
      • Resource utilizations such as CPU utilization of VM instances and memory utilization of hosts
      • Resource capacities such as available number of IP addresses and total number of running VM instances
    • Event collection: collects events predefined on the Cloud, such as host disconnection and VM HA enabling.
    • Alarm: triggers alarms on time-series data or events.
    • Audit: records all operations and allows queries.
    • Customization: allows you to customize alarms and message templates and use predefined alarm templates and resource groups.
      • The following three types of alarms are supported:
        • Resource alarm: triggers alarms on time-series data. For example, you can configure an alarm for VM instances. If the CPU utilization of a VM instance exceeds 80% by five consecutive minutes, send an alarm message to an email address.
        • Event alarm: triggers alarms on events, also called event subscription. For example, you can configure an alarm for host disconnection. If a host is disconnected, an alarm message is sent to DingTalk.
        • Extended alarm: receives alarm messages from message sources. For example, if a Ceph Enterprise storage pool is downgraded, an alarm message is sent to the system of the Cloud.
      • A message template specifies the text template of a resource alarm message or event alarm message sent to an SNS system.
        • A message template and message recovery template are provided by the system. If you do not create a template, the system uses the predefined templates.
        • You can create multiple message templates and can set only one template as the default template. Messages are formatted by using the default template.
        • You can use ${} in a template to quote variables configured in an alarm or event.
        • You can configure email, DingTalk, text message, and Microsoft Teams as an endpoint in a message template. Messages sent by using email, DingTalk, text message, or Microsoft Teams are sent in the specified format.
      • A message source is used to take over extended alarm messages. If you configure alarms for message sources, extended alarm messages can be sent to various endpoints. This enables centralized management of alarm messages and improves O&M efficiencies. You can configure a message source to take over alarm messages of Ceph Enterprise.
      • An alarm template is a template of alarm rules. If you associate an alarm template with a resource group, an alarm is created to monitor the resources in the group.
      • A resource group consists of resources grouped based on your business needs. If you associate an alarm template with a resource group, the alarm rules specified by the template take effect on all the resources in the group.
  • SNS:

    SNS sends alarm messages to the specified endpoints. The supported types of endpoints include the system, emails, DingTalk, HTTP applications, text messages, and Microsoft Teams.

    Endpoints:
    • The system provides the system-type endpoint. If you associate an alarm with this endpoint, alarm messages will be displayed below the Recent Message button in the top right corner of the UI.
    • You can also create an endpoint of the email, DingTalk, HTTP application, text message, or Microsoft Teams type.

Characteristics

ZStack Cube Ultimate monitoring and alarm has the following characteristics:
  • Provides rich metric items to comprehensively monitor and alarm the core resources as well as events of the Cloud platform.
  • Supports types of endpoints including system, emails, DingTalk, HTTP application, text messages, and Microsoft Teams for subscription topics. You can choose an appropriate endpoint to receive alarm messages according to the actual situation.
  • One alarm can monitor multiple resources at the same time.
  • Emails, DingTalk, text messages, and Microsoft Teams support customized alarm message templates. You can set alarm message templates on demand and quickly locate key information from alarm messages.
  • Supports for creating a template of alarm rules. If you associate an alarm template with a resource group, an alarm is created to monitor the resources in the group.

Scenarios

The function of monitoring and alarm monitors the core resources and events of the Cloud platform and sets up an alarm receiving mechanism. When core resources are abnormal, the monitoring and alarm will make real-time responses according to the alarm level to help O&M personnel quickly locate and solve the problem.

Global Setting

  • Monitoring data is retained locally for 6 months by default, and you can customize the monitoring data retention period in the basic settings as follows:

    On the main menu of ZStack Cube Ultimate, choose Settings > Global Setting > Basic. Then, the Basic tab is displayed. You can set Monitoring Data Retention Period. Enter an integer between 1 and 12. Default: 6. Unit: month.

  • Monitoring data is retained locally in a size of 50GB by default, and you can customize the monitoring data retention size in the basic settings as follows:

    On the main menu of ZStack Cube Ultimate, choose Settings > Global Setting > Basic. Then, the Basic tab is displayed. You can set Monitoring Data Retention Size based on your needs. Default: 50 GB.

  • ZStack Cube Ultimate supports receiving extended alarm messages. On the main menu, choose Settings > Global Setting > Advanced. Then, the Advanced tab is displayed. You need to turn on the Extended Alarm Notification switch to use the extended alarm function.

Alarm

Create an Alarm

On the main menu of ZStack Cube Ultimate, choose Platform O&M > Cloud Monitoring > Alarm Service > Alarm. Then, the Alarm page is displayed.

The following lists the three alarm creation scenarios:
  • Create a resource alarm
  • Create an event alarm
  • Create an extended alarm

Create Resource Alarm

The system provides default resource alarms. In addition, you can customize resource alarms based on your needs. On the Resource Alarm tab, click Create Resource Alarm. Then, the Create Resource Alarm page is displayed.

On the displayed page, set the following parameters:
  • Name: Enter a name for the resource alarm.
  • Description: Optional. Enter a description for the resource alarm.
  • Resource Type: Select a resource type. Valid values: VM Instance, Baremetal Instance, Elastic Baremetal Instance, VPC vRouter, Image, Backup Storage, System Data Directory, Host, L3 Network, Volume, VIP, Primary Storage, Listener, Management Node, Project Resource, and CDP Task.

    Note that you can select Project Resource and CDP Task only after you have purchased Tenant Management License and Continuous Data Protection (CDP) License, respectively.

  • Metric Item: Select a metric item of the selected resource type.
    Note:
    • Multiple metric items are available for every type of resources. You can select a metric item based on your business needs.
    • Some metric items are associated with additional parameter settings. If you select such metric items, you need to configure the additional parameter settings.
    • Some metrics items are available only after the agent is installed on the related resource. .
    • If you need to monitor memory data, we recommend that you use internal monitoring for this purpose. This is because internal monitoring yields a more accurate memory data than external monitoring.
    • You can create resource alarms for key cloud resources such as VM instances, hosts, and primary storage on the details page of the resources.
  • Alarm Coverage: Select one or more resources on which the alarm takes effect.
    • If you select multiple resources of the specified type, all the resources for which the alarm is configured are monitored. If the trigger condition of a resource is met, the alarm is triggered.
    • If you select only one resource of the specified type, the resource for which the alarm is configured is monitored. If the trigger condition of the resource is met, the alarm is triggered.
      Note:
      • You can configure fine-grained alarms for a resource.
      • For example, you can configure an alarm to monitor the utilization of a CPU of a VM instance.
  • Alarm Trigger Rule: Select a comparison symbol and specify a threshold and duration.
  • Alarm Interval: Select an alarm interval.
    • Only 1 time:
      • Alarm is triggered only once for a resource.
        For example,
        • Assume that you configure an alarm for multiple resources. If the trigger condition of a resource is met, the alarm is triggered. After that, even if the trigger condition of this resource is met again, the alarm is no longer triggered.

          Assume that you configure an alarm for a resource. If the trigger condition of the resource is met, the alarm is triggered. After that, even if the trigger condition of the resource is met again, the alarm is no longer triggered.

      • The alarm message is sent to the endpoint (if specified) for only once. In addition, the alarm message is displayed on Message Center only once.
      • If the resource recovers but later meets the trigger condition again, the one-time alarm is triggered again.
    • Repetitive Alarm
      • Alarm is triggered multiple times for a resource.
        For example,
        • Assume that you configure an alarm for multiple resources. If the trigger condition of a resource is met, the alarm is triggered. If the resource keeps meeting the trigger condition, the alarm is repetitively triggered based on the alarm interval.

          Assume that you configure an alarm for a resource. If the trigger condition of the resource is met, the alarm is triggered. If the resource keeps meeting the trigger condition, the alarm is repetitively triggered based on the alarm interval.

      • Each time the alarm is triggered, the alarm message is sent to the endpoint (if specified). In addition, every alarm message is displayed on Message Center.
  • Emergency Level: Set an emergency level. Valid values: Emergent, Major, and Info. Alarms of different emergency levels correspond to alarm messages of different emergency levels.
  • Alarm Recovery Notification: Optional. If enabled, when a resource monitored by a resource alarm recovers from alarmed status, the system receives a notification. The recovery notification is sent according to the default recovery message template. You can customize the message content on the Message Template page.
  • Endpoint: Optional. If specified, alarm messages are sent to the specified endpoint.
    Note:
    • You can specify multiple endpoints.
    • You can specify the system endpoint or customize an endpoint.
Figure 3. Create Resource Alarm


Create Event Alarm

The system provides default event alarms. In addition, you can customize event alarms based on your needs. On the Event Alarm tab, click Create Event Alarm. Then, the Create Event Alarm page is displayed.

On the displayed page, set the following parameters:
  • Resource Type: Select a resource type. Valid values: VM Instance, VPC vRouter, Backup Storage, Management Node, Host, Primary Storage, vCenter, Backup Job, Project Resource, and CDP Task.

    Note that you can select Project Resource and CDP Task only after you have purchased Tenant Management License and Continuous Data Protection (CDP) License, respectively.

  • Metric Item: Select a metric item of the selected resource type.
  • Emergency Level: Set an emergency level. Valid values: Emergent, Major, and Info. Alarms of different emergency levels correspond to alarm messages of different emergency levels.
  • Endpoint: Optional. If specified, alarm messages are sent to the specified endpoint.
    Note:
    • You can specify multiple endpoints.
    • You can specify the system endpoint or customize an endpoint.
Figure 4. Create Event Alarm


Note:
  • An event alarm is triggered only when the configured event occurs. The repetitive alarm mechanism is not available for event alarms.
  • When a resource monitored by an event alarm recovers from alarmed status, the system receives a notification. The recovery notification is sent according to the default recovery message template. You can customize the message content on the Message Template page.
  • If the configured event occurs again, the event alarm is triggered again.

Create Extended Alarm

Before you can create an extended alarm, you need to enable the extended alarm feature. To do this, choose Settings > Platform Setting > Global Setting > Advanced and turn on the Extended Alarm Notification switch.

Then you can create an extended alarm to receive extended alarm messages. On the Extended Alarm tab, click Create Extended Alarm. Then the Create Extended Alarm page is displayed. On the displayed page, set the following parameters:
  • Name: Enter a name for the extended alarm.
  • Message Source: Select a source where you need to receive alarm messages.
  • Endpoint: Optional. If specified, alarm messages are sent to the specified endpoint.
    Note:
    • You can specify multiple endpoints.
    • You can specify the system endpoint or customize an endpoint.
Figure 5. Create Extended Alarm


One-click Alarm

A one-click alarm integrates multiple metrics of a resource. You can create one-click alarms for multiple resources to monitor these resources.

Alarm Template

Create an Alarm Template

On the main menu of ZStack Cube Ultimate, choose Platform O&M > Cloud Monitoring > Alarm Service > Alarm Template. On the Alarm Template page, click Create Alarm Template. Then, the Create Alarm Template page is displayed.

On the displayed page, set the following parameters:
  • Name: Enter a name for the alarm template.
  • Description: Optional. Enter a description for the alarm template.
  • Resource Type: add an alarm rule to the template.
    • Alarm Type: Select resource alarm or event alarm.
    • Resource Type: Select a resource type.
      • If you create a resource alarm rule, you can select the following resource types: VM Instance, Baremetal Instance, Elastic Baremetal Instance, VPC vRouter, Backup Storage, Host, L3 Network, VIP, Primary Storage, Listener, and License.
      • If you create an event alarm rule, you can select the following resource types: VM Instance, VPC vRouter, Backup Storage, Host, and Primary Storage.
    • Add Rule: Add an alarm rule for the selected resource.
Figure 6. Create Alarm Rule


Resource Group

Create a Resource Group

On the main menu of ZStack Cube Ultimate, choose Platform O&M > Cloud Monitoring > Alarm Service > Resource Group. On the Resource Group page, click Create Resource Group. Then, the Create Resource Group page appears.

On the displayed page, set the following parameters:
  • Name: Enter a name for the resource group.
  • Description: Optional. Enter a description for the resource group.
  • Resource: Add a resource to the resource group.
  • Alarm Template: Optional. Associate a resource group with an alarm template. Then the alarm template applies to all resources in the group. You can also associate an alarm template after the resource group is created.
    Note: You can associate a resource group with only one alarm template.
  • Endpoint: Optional. If specified, alarm messages are sent to the specified endpoint.
    Note:
    • You can specify multiple endpoints.
    • You can specify the system endpoint or customize an endpoint.
Figure 7. Create Resource Group


Message Template

Create a Message Template

On the main menu of ZStack Cube Ultimate, choose Platform O&M > Cloud Monitoring > Alarm Configuration > Message Template. On the Message Template page, click Create Message Template. Then, the Create Message Template page appears.

On the displayed page, set the following parameters:
  • Name: Enter a name for the message template.
  • Description: Optional. Enter a description for the message template.
  • Type: Select the platform type of an endpoint. Valid values: Email, DingTalk, Microsoft Teams, and SMS.
  • Alarm Type: Select an alarm type. Valid values: Resource Alarm and Event Alarm.
  • Alarm Message Title: Set the title of alarm messages. You can customize a title or use the sytstem template. Currently, you cannot set a message title for SMS messages.

    The following is a message title template:

    Resource Alarm:
    Alarm ${ALARM_METRIC} ${ALARM_COMPARISON_OPERATOR} ${ALARM_THRESHOLD} ${ALARM_CURRENT_STATUS}
    Event Alarm:
    ${EVENT_NAME} alarm occurs.
  • Alarm Message Text: Customize an alarm message text template or use the system template.

    The following is a message template for endpoints of the email and DingTalk types:

    Resource Alarm:
    Alarm ${ALARM_NAME} State Changes To ${ALARM_CURRENT_STATUS}
    
    Alarm Details
    UUID: ${ALARM_UUID}
    Resource Namespace: ${ALARM_NAMESPACE}
    Trigger Condition: ${ALARM_METRIC} ${ALARM_COMPARISON_OPERATOR} ${ALARM_THRESHOLD}
    Trigger Condition Duration: ${ALARM_DURATION} seconds
    Previous Status: ${ALARM_PREVIOUS_STATUS}
    Current Value: ${ALARM_CURRENT_VALUE}
    Tag: ${ALARM_LABELS.join(",")}
    Event Alarm:
    Event Details:
    Name:${EVENT_NAME}
    Resource Type: ${EVENT_NAMESPACE}
    Emergency Level:${EVENT_EMERGENCY_LEVEL}
    Resource UUID:${EVENT_RESOURCE_ID}
    Name:${EVENT_RESOURCE_NAME}
    Alarm Trigger Time:${EVENT_TIME}
    Event Subscription UUID:${EVENT_SUBSCRIPTION_UUID}
    Error:${EVENT_ERROR}
    Note: Message templates for DingTalk-type endpoints must follow the Markdown syntax. DingTalk supports the subset of Markdown syntax. For more information, see DingTalk official website.
    The following is a message template for endpoints of the Microsoft Teams type:
    • Resource alarm:
      {
        "activityTitle": "Alarm ${ALARM_NAME} ${TITLE_ALARM_RESOURCE_NAME} State Changes To ${ALARM_CURRENT_STATUS}",
        "facts": [
          {
            "name": "Alarm Details",
            "value": null
          },
          {
            "name": "UUID",
            "value": "${ALARM_UUID}"
          },
          {
            "name": "Resource Type",
            "value": "${ALARM_NAMESPACE}"
          },
          {
            "name": "Trigger Condition",
            "value": "${ALARM_METRIC} ${ALARM_COMPARISON_OPERATOR} ${ALARM_THRESHOLD}"
          },
          {
            "name": "Trigger Condition Duration",
            "value": "${ALARM_DURATION} seconds"
          },
          {
            "name": "Previous Status",
            "value": "${ALARM_PREVIOUS_STATUS}"
          },
          {
            "name": "Current Value",
            "value": "${ALARM_CURRENT_VALUE}"
          },
          {
            "name": "Alarm Resource UUID",
            "value": "${ALARM_RESOURCE_ID}"
          },
          {
            "name": "Alarm Trigger Time",
            "value": "${ALARM_TIME}"
          },
          {
            "name": "Alarm Resource Name",
            "value": "${ALARM_RESOURCE_NAME}"
          },
          {
            "name": "Emergency Level",
            "value": "${ALARM_EMERGENCY_LEVEL}"
          },
          {
            "name": "Tag",
            "value": "${ALARM_LABELS.join(\",\")}"
          }
        ]
      }
    • Even alarm:
      {
        "activityTitle": "Event ${EVENT_NAME} Happened",
        "facts": [
          {
            "name": "Event Details",
            "value": null
          },
          {
            "name": "Name",
            "value": "${EVENT_NAME}"
          },
          {
            "name": "Resource Type",
            "value": "${EVENT_NAMESPACE}"
          },
          {
            "name": "Emergency Level",
            "value": "${EVENT_EMERGENCY_LEVEL}"
          },
          {
            "name": "Alarm Resource UUID",
            "value": "${EVENT_RESOURCE_ID}"
          },
          {
            "name": "Alarm Resource Name",
            "value": "${EVENT_RESOURCE_NAME}"
          },
          {
            "name": "Alarm Trigger Time",
            "value": "${EVENT_TIME}"
          },
          {
            "name": "Event Subscription UUID",
            "value": "${EVENT_SUBSCRIPTION_UUID}"
          },
          {
            "name": "Error",
            "value": "${EVENT_ERROR}"
          }
        ]
      }
    Note: Message template for endpoints of the Microsoft Teams type must follow the Webhook syntax of Microsoft Teams. For more information, see Microsoft Teams official website.
    The following is a message template for endpoints of the SMS type:
    • Resource alarm:
      Alarm: ${ALARM_NAME}, Name: ${ALARM_RESOURCE_NAME}, Trigger Condition: ${ALARM_CONDITION}, Emergency Level: ${ALARM_EMERGENCY_LEVEL}, Current Value: ${ALARM_CURRENT_VALUE}
    • Event alarm:
      Event Name: ${EVENT_NAME}, Name: ${EVENT_RESOURCE_NAME}, Emergency Level: ${EVENT_EMERGENCY_LEVEL}, Error: ${EVENT_ERROR}
    Note: Before you can customize a message template for SMS endpoint, you need to apply for and obtain a third-party SMS signature and SMS template. Currently, only Alibaba Cloud SMS is supported. If you need to modify a template, you need to modify on the third-party side. In addition, you need to apply for the signature and template again.
  • Recovery Message Title: When a monitored resource recovers from an alarm status, the Cloud sends alarm recovery messages to the selected endpoint. You can customize the title of the recovery messages as needed. SMS-type endpoints do not support recovery messages.
  • Recovery Message Text: Set the text content of the recovery meassage.
  • Make Default: Optional. Set the current message template as the default template.
Figure 8. Create Message Template




Message Source

Create a Message Source

Before you can create a message source, you need to enable the extended alarm feature. To do this, choose Settings > Platform Setting > Global Setting > Advanced and turn on the Extended Alarm Notification switch.

On the main menu of ZStack Cube Ultimate, choose Platform O&M > Cloud Monitoring > Alarm Configuration > Message Source. On the Message Source page, click Create Message Source. Then, the Create Message Source page appears.

On the displayed page, set the following parameters:
  • Name: Enter a name for the message source.
  • Description: Optional. Enter a description for the message source.
  • Message Source Type: Select the type of message source. Currently, only Ceph Enterprise is supported.
  • Login Address and Token: Enter the login address of the message source and the access token obtained on the message source page, in the format of http://{Message Source IP Address}:{Port}/v1/alerts/?token={Access Token}
  • Alarm Message Conversion Template: Convert third-party alarm messages into alarm messages that conform to the format required on the Cloud. The system provides a conversion template that you can use to customize the parameters.
    Example:
    {
        "product":"Ceph Enterprise",
        "service":"Ceph Enterprise",
        "message":"${resource_type + '[' + resource_name+'] ' + group + ' ' + alert_value}",
        "metric":"${resource_type + '::' + group}",
        "alertLevel":"${level == 'info' ? 'Normal' : level == 'warning' ? 'Important' : 'Emergent'}",
        "alertTime":"${create}",
        "dimensions":"{'resource_name':'${resource_name}'}",
        "dataSource":"Ceph Enterprise"
    } 

Endpoint

Create an Endpoint

On the main menu of ZStack Cube Ultimate, choose Platform O&M > Cloud Monitoring > Alarm Configuration > Endpoint. On the Endpoint page, click Create Endpoint. Then, the Create Endpoint page appears.

The following lists the four endpoint creation scenarios:
  • Create an endpoint of the email type
  • Create an endpoint of the DingTalk type
  • Create an endpoint of the HTTP application type
  • Create an endpoint of the SMS type
  • Create an endpoint of the Microsoft Teams type

Create Endpoint of Email Type

  • Messages sent to topics are sent to the specified email address via an email server.
  • You can customize a message template or use the system message template to send email messages in a unified format.
  • You need to add an email server to the Cloud and test the availability of the server before you can use the email server to send messages.
On the displayed page, set the following parameters:
  • Name: Enter a name for the endpoint.
  • Description: Optional. Enter a description for the endpoint.
  • Type: Select Email.
  • Email Address: Enter one or more email addresses. You can enter a maximum of 100 email addresses.
  • Email Server: Enter an email server that is added to the Cloud.
    • Test: Test the availability of the email server.
  • Message Language: Select a language for alarm messages. Valid values: Simplified Chinese and English.
Figure 9. Create Endpoint of Email Type


Create Endpoint of DingTalk Type

  • Messages sent to topics are sent to the specified DingTalk robot address via DingTalk. If you specify a contact, the DingTalk user that owns the phone number will be notified of the messages.
  • You can customize a message template or use the system message template to send email messages in a unified format.
  • You need to create an alarm message template of DingTalk type that follows the Markdown syntax. DingTalk supports the subset of Markdown syntax. For more information, see DingTalk official website.
  • Name: Enter a name for the endpoint.
  • Description: Optional. Enter a description for the endpoint.
  • Type: Select DingTalk.
  • Address: Enter a DingTalk robot address.
  • Contact: Optional. Specify all members or specific members in the group.
    Note: If you need to specify a member, enter the phone number of the member, for example, +86-13800000000.
  • Message Language: Select a language for alarm messages. Valid values: Simplified Chinese and English.
Figure 10. Create Endpoint of DingTalk Type


Create Endpoint of HTTP Application Type

  • Messages sent to topics are sent to the specified HTTP address by using the HTTP POST method.
  • If you set a username and password for the specified HTTP application, enter the username and password for the endpoint.
  • Name: Enter a name for the endpoint.
  • Description: Optional. Enter a description for the endpoint.
  • Type: Select HTTP Application.
  • Address: Enter the address of an HTTP application.
    Note:
    • If the HTTP application is managed by a single management node, the IP address is 127.0.0.1 by default.
    • If the HTTP application is managed in a dual-MN environment, the IP address is a VIP.
  • User Name: Optional. Enter the username of the HTTP application.
  • Password: Optional. Enter the password of the HTTP application.
Figure 11. Create Endpoint of HTTP Application Type


Create Endpoint of SMS Type

  • Messages sent to topics are sent to the specified phone numbers via text messages.
  • You need to create a message template and set it as the default template. Then text alarm messages are sent according to the template.
  • Name: Enter a name for the endpoint.
  • Description: Optional. Enter a description for the endpoint.
  • Type: Select SMS.
  • AccessKey: Enter a third-party AccessKey pair.
  • Phone Number: Enter the phone numbers that receive text messages.
Figure 12. Create Endpoint of SMS Type


Create Endpoint of Microsoft Teams Type

  • Messages sent to topics are sent to the specified Microsoft Teams via Webhook.
  • You can create a message template or use the system template for alarm messages to be sent in a unified format.
  • Name: Enter a name for the endpoint.
  • Description: Optional. Enter a description for the endpoint.
  • Type: Select Microsoft Teams.
  • Address: Enter the Webhook address obtained in the Microsoft Teams.
  • Message Language: Select a language for alarm messages. Valid values: Simplified Chinese and English.
Figure 13. Create Endpoint of Microsoft Teams Type


Alarm Item Overview

Resource Alarm Items

Default Alarm Items

resource type default alarm alarm item description
VM instance VM instancememoryused percentage VM instancememoryused percentage≥80%
  • Monitors cloud platformall VM instance .
  • any VM instancememoryused percentageis greater than or equal to 80%, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
VM instanceaverage CPUusage VM instanceaverage CPUusage≥80%
  • Monitors cloud platformall VM instance .
  • any VM instanceaverage CPUusageis greater than or equal to 80%, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
host hostroot diskusagealarm hostroot diskusage≥80%
  • Monitors cloud platformall host .
  • any hostroot diskusageis greater than or equal to 80%, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
CPUtemperaturealarm CPUtemperature≥80℃
  • Monitors cloud platformall host .
  • any hostCPUtemperatureis greater than or equal to 80℃, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
SSDtemperaturealarm SSDtemperature≥80℃
  • Monitors cloud platformall host .
  • any hostSSDtemperatureis greater than or equal to 80℃, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
SSDremaining lifealarm SSDremaining life≤10%
  • Monitors cloud platformall host .
  • any hostSSDremaining lifeis less than or equal to 10%, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
hostaverage CPUusage hostaverage CPUusage≥80%
  • Monitors cloud platformall host .
  • any hostaverage CPUusagefor 5minutesis greater than or equal to 80%, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
hostmemoryused percentage the hostused memorycapacitypercentage≥80%
  • Monitors cloud platformall host .
  • any hostmemoryused percentagefor 5minutesis greater than or equal to 80%, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
image server image serverstoragecan use capacityalarm image storagecan use capacitypercentage<20%
  • Monitors cloud platformall image server .
  • any image servercan use capacitypercentageis less than 20%, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
primary storage primary storagecan use capacityalarm the primary storagecan use capacitypercentage<20%
  • Monitors cloud platformall primary storage .
  • any primary storagecan use capacitypercentageis less than 20%, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
primary storagecan use physical capacityalarm the primary storagecan use physical capacitypercentage<20%
  • Monitors cloud platformall primary storage .
  • any primary storagecan use physical capacitypercentageis less than 20%, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
management node dual management nodesdatabase is not synchronizedalarm dual management nodesdatabase is not synchronized
  • Monitors multiple management nodesenvironmentcountdatabasestatus .
  • If for 1hourdetectedmultiple management nodescountdatabasehas data is not synchronized, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
arbiterIPnot can reachalarm arbiterIPnot can reach
  • Monitors multiple management nodesenvironmentarbiterIPstatus .
  • If for 10minutesdetectedarbiterIPnot can reach, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
systemdata directory systemdata directorydiskcapacityalarm management nodedata directorydiskoccupy use rate≥70%
  • Monitors cloud platformall data directorydiskcapacity .
  • any management nodedata directorydiskoccupy use rateis greater than or equal to 70%, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
license licenseexpirationtimealarm defaultlicenseexpirationtime≤15days
  • Monitors cloud platformlicense, modulelicense and distributed storagelicense .
  • any licenseexpirationtimeis less than or equal to 15days, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
CDPtask (requiresfor data protectionCDPmodulelicense) CDPtaskused capacityalarm CDPtaskused capacityoccupyplannedcapacitypercentage>80%
  • Monitors cloud platformin all CDPtaskused capacityoccupyplannedcapacity of percentage .
  • any CDPtask of used capacity and plannedcapacity of occupyratioexceeds80% triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
CDPtaskRPOoffsetalarm RPOoffsettime>5minutes
  • Monitors cloud platformin all CDPtask of RPOoffsetstatus .
  • any CDPtask of RPOoffsettimeexceeds5minutes triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .

customalarm item

resource type subtype alarm item description
VM instance CPU CPUusage whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VM instance of CPUusage, any VM instanceany CPUusagemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VM instancespecifiedCPU of usage, meets the alarm condition triggers an alarm .
CPUidle rate whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VM instance of CPUidle rate, any VM instanceany CPUidle ratemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VM instancespecifiedCPU of idle rate, meets the alarm condition triggers an alarm .
average CPUusage batch-monitors multipleVM instance of average CPUusage, any VM instance of average CPUusagemeets the alarm condition triggers an alarm .
allCPUusage batch-monitors multipleVM instance of CPUusage, any VM instance of allCPUusagesummeets the alarm condition triggers an alarm .
Note: percentagesum, can abilityis greater than 100% .
allCPUidle rate batch-monitors multipleVM instance of CPUidle rate, any VM instance of allCPUidle ratesummeets the alarm condition triggers an alarm .
Note: percentagesum, can abilityis greater than 100% .
CPUusage(requires installation ofagent) whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VM instance of CPUusage, any VM instanceany CPUusagemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VM instancespecifiedCPU of usage, meets the alarm condition triggers an alarm .
disk diskreadIOPS whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VM instance of all diskreadIOPS, any VM instanceany diskreadIOPSmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VM instancespecifieddisk of readIOPS, meets the alarm condition triggers an alarm .
alldiskreadIOPS batch-monitors multipleVM instance of diskreadIOPS, any VM instanceall disk of readIOPSsummeets the alarm condition triggers an alarm .
diskwriteIOPS whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VM instance of all diskwriteIOPS, any VM instanceany diskwriteIOPSmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VM instancespecifieddisk of writeIOPS, meets the alarm condition triggers an alarm .
alldiskwriteIOPS batch-monitors multipleVM instance of diskwriteIOPS, any VM instanceall disk of writeIOPSsummeets the alarm condition triggers an alarm .
diskread speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VM instance of all diskread speed, any VM instanceany diskread speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VM instancespecifieddisk of read speed, meets the alarm condition triggers an alarm .
alldiskread speed batch-monitors multipleVM instance of diskread speed, any VM instanceall disk of read speedsummeets the alarm condition triggers an alarm .
diskwrite speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VM instance of all diskwrite speed, any VM instanceany diskwrite speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VM instancespecifieddisk of write speed, meets the alarm condition triggers an alarm .
alldiskwrite speed batch-monitors multipleVM instance of diskwrite speed, any VM instanceall disk of write speedsummeets the alarm condition triggers an alarm .
alldiskremainingcapacity(requires installation ofagent) batch-monitors multipleVM instance of diskremainingcapacity, any VM instanceall disk of remainingcapacitysummeets the alarm condition triggers an alarm .
alldiskremainingcapacitypercentage(requires installation ofagent) batch-monitors multipleVM instance of diskremainingcapacitypercentage, any VM instancealldiskremainingcapacitypercentage (percentage=all diskremainingcapacitysum/all diskcapacitysum)meets the alarm condition triggers an alarm .
alldiskusedcapacity(requires installation ofagent) batch-monitors multipleVM instance of diskusedcapacity, any VM instanceall disk of usedcapacitysummeets the alarm condition triggers an alarm .
alldiskusedcapacitypercentage(requires installation ofagent) batch-monitors multipleVM instance of diskusedcapacitypercentage, any VM instancealldiskusedcapacitypercentage (percentage=all diskusedcapacitysum/all diskcapacitysum)meets the alarm condition triggers an alarm .
diskusedcapacity(requires installation ofagent) whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VM instance of diskusedcapacity, any VM instanceany diskusedcapacitymeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VM instancespecifieddisk of usedcapacity, meets the alarm condition triggers an alarm .
diskusedcapacitypercentage(requires installation ofagent) whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VM instance of diskusedcapacitypercentage, any VM instanceany diskusedcapacitypercentagemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VM instancespecifieddisk of usedcapacitypercentage, meets the alarm condition triggers an alarm .
diskremainingcapacitypercentage(requires installation ofagent) whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VM instance of diskremainingcapacitypercentage, any VM instanceany diskremainingcapacitypercentagemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VM instancespecifieddisk of remainingcapacitypercentage, meets the alarm condition triggers an alarm .
diskremainingcapacity(requires installation ofagent) whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VM instance of diskremainingcapacity, any VM instanceany diskremainingcapacitymeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VM instancespecifieddisk of remainingcapacity, meets the alarm condition triggers an alarm .
NIC NICinbound speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VM instance of NICinbound speed, any VM instanceany NICinbound speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VM instancespecifiedNIC of inbound speed, meets the alarm condition triggers an alarm .
allNICinbound speed batch-monitors multipleVM instance of NICinbound speed, any VM instanceall NICinbound speedsummeets the alarm condition triggers an alarm .
NICinbound packet count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VM instance of NICinbound packet count, any VM instanceany NICinbound packet countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VM instancespecifiedNIC of inbound packet count, meets the alarm condition triggers an alarm .
allNICinbound packet count batch-monitors multipleVM instance of NICinbound packet count, any VM instanceall NICinbound packet countsummeets the alarm condition triggers an alarm .
NICinbound error count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VM instance of NICinbound error count, any VM instanceany NICinbound error countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VM instancespecifiedNIC of inbound error count, meets the alarm condition triggers an alarm .
allNICinbound error count batch-monitors multipleVM instance of NICinbound error count, any VM instanceall NICinbound error countsummeets the alarm condition triggers an alarm .
NICoutbound speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VM instance of NICoutbound speed, any VM instanceany NICoutbound speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VM instancespecifiedNIC of outbound speed, meets the alarm condition triggers an alarm .
allNICoutbound speed batch-monitors multipleVM instance of NICoutbound speed, any VM instanceall NICoutbound speedsummeets the alarm condition triggers an alarm .
NICoutbound packet count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VM instance of NICoutbound packet count, any VM instanceany NICoutbound packet countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VM instancespecifiedNIC of outbound packet count, meets the alarm condition triggers an alarm .
allNICoutbound packet count batch-monitors multipleVM instance of NICoutbound packet count, any VM instanceall NICoutbound packet countsummeets the alarm condition triggers an alarm .
NICoutbound error count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VM instance of NICoutbound error count, any VM instanceany NICoutbound error countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VM instancespecifiedNIC of outbound error count, meets the alarm condition triggers an alarm .
allNICoutbound error count batch-monitors multipleVM instance of NICoutbound error count, any VM instanceall NICoutbound error countsummeets the alarm condition triggers an alarm .
memory memoryidlecapacity batch-monitors multipleVM instance of memoryidlecapacity, any VM instance of memoryidlecapacitymeets the alarm condition triggers an alarm .
memoryidlepercentage batch-monitors multipleVM instance of memoryidlepercentage, any VM instance of memoryidlepercentagemeets the alarm condition triggers an alarm .
memoryused capacity batch-monitors multipleVM instance of memoryused capacity, any VM instance of memoryused capacitymeets the alarm condition triggers an alarm .
memoryused percentage batch-monitors multipleVM instance of memoryused percentage, any VM instance of memoryused percentagemeets the alarm condition triggers an alarm .
memoryused percentage(requires installation ofagent) batch-monitors multipleVM instance of memoryused percentage, any VM instance of memoryused percentagemeets the alarm condition triggers an alarm .
other VM instancequantity monitorcloud platformin all KVMVM instancequantity, meets the alarm condition triggers an alarm .
runningVM instancequantity monitorcloud platformin all runningstatus of KVMVM instancequantity, meets the alarm condition triggers an alarm .
runningVM instancepercentage monitorcloud platformin all runningstatus of KVMVM instancepercentage, meets the alarm condition triggers an alarm .
stopVM instancequantity monitorcloud platformin all stopstatus of KVMVM instancequantity, meets the alarm condition triggers an alarm .
stopVM instancepercentage monitorcloud platformin all stopstatus of KVMVM instancepercentage, meets the alarm condition triggers an alarm .
otherstatusVM instancequantity monitorcloud platformin all otherstatus (not includes: stop/running) of KVMVM instancequantity, meets the alarm condition triggers an alarm .
otherstatusVM instancepercentage monitorcloud platformin all otherstatus (not includes: stop/running) of KVMVM instancepercentage, meets the alarm condition triggers an alarm .
bare metal host (installedbare metalmanagemodulelicense) CPU CPUusage whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected bare metal hostsall CPU of usage, any metric of any bare metal hostCPUusagemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of a bare metal hostCPU of usage, meets the alarm condition triggers an alarm .
disk diskreadIOPS whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected bare metal hostsall disk of readIOPS, any metric of any bare metal hostdiskreadIOPSmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of a bare metal hostdisk of readIOPS, meets the alarm condition triggers an alarm .
diskwriteIOPS whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected bare metal hostsall disk of writeIOPS, any metric of any bare metal hostdiskwriteIOPSmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of a bare metal hostdisk of writeIOPS, meets the alarm condition triggers an alarm .
diskread speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected bare metal hostsall disk of read speed, any metric of any bare metal hostdiskread speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of a bare metal hostdisk of read speed, meets the alarm condition triggers an alarm .
diskwrite speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected bare metal hostsall disk of write speed, any metric of any bare metal hostdiskwrite speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of a bare metal hostdisk of write speed, meets the alarm condition triggers an alarm .
diskusedcapacity whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected bare metal hostsall disk of usedcapacity, any metric of any bare metal hostdiskusedcapacitymeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of a bare metal hostdisk of usedcapacity, meets the alarm condition triggers an alarm .
diskusedcapacitypercentage whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected bare metal hostsall disk of usedcapacitypercentage, any metric of any bare metal hostdiskusedcapacitypercentagemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of a bare metal hostdisk of usedcapacitypercentage, meets the alarm condition triggers an alarm .
diskremainingcapacitypercentage whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected bare metal hostsall disk of remainingcapacitypercentage, any metric of any bare metal hostdiskremainingcapacitypercentagemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of a bare metal hostdisk of remainingcapacitypercentage, meets the alarm condition triggers an alarm .
diskremainingcapacity whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected bare metal hostsall disk of remainingcapacity, any metric of any bare metal hostdiskremainingcapacitymeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of a bare metal hostdisk of remainingcapacity, meets the alarm condition triggers an alarm .
NIC NICinbound speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected bare metal hostsall NIC of inbound speed, any metric of any bare metal hostNICinbound speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of a bare metal hostNIC of inbound speed, meets the alarm condition triggers an alarm .
NICinbound packet count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected bare metal hostsall NIC of inbound packet count, any metric of any bare metal hostNICinbound packet countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of a bare metal hostNIC of inbound packet count, meets the alarm condition triggers an alarm .
NICinbound error count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected bare metal hostsall NIC of inbound error count, any metric of any bare metal hostNICinbound error countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of a bare metal hostNIC of inbound error count, meets the alarm condition triggers an alarm .
NICoutbound speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected bare metal hostsall NIC of outbound speed, any metric of any bare metal hostNICoutbound speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of a bare metal hostNIC of outbound speed, meets the alarm condition triggers an alarm .
NICoutbound packet count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected bare metal hostsall NIC of outbound packet count, any metric of any bare metal hostNICoutbound packet countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of a bare metal hostNIC of outbound packet count, meets the alarm condition triggers an alarm .
NICoutbound error count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected bare metal hostsall NIC of outbound error count, any metric of any bare metal hostNICoutbound error countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of a bare metal hostNIC of outbound error count, meets the alarm condition triggers an alarm .
memory memorytotal amount batch-monitors multiplebare metal host of memorytotal amount, any bare metal host of memorytotal amountmeets the alarm condition triggers an alarm .
remainingmemoryamount batch-monitors multiplebare metal host of remainingmemoryamount, any bare metal host of remainingmemoryamountmeets the alarm condition triggers an alarm .
used memoryamount batch-monitors multiplebare metal host of used memoryamount, any bare metal host of used memoryamountmeets the alarm condition triggers an alarm .
can use memoryamount batch-monitors multiplebare metal host of can use memoryamount, any bare metal host of can use memoryamountmeets the alarm condition triggers an alarm .
remainingmemorypercentage batch-monitors multiplebare metal host of memoryused percentage, any bare metal host of memoryused percentagemeets the alarm condition triggers an alarm .
memoryusage batch-monitors multiplebare metal host of memoryusage, any bare metal host of memoryusagemeets the alarm condition triggers an alarm .
elastic bare metal instance (installedbare metalmanagemodulelicense) CPU CPUusage whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected elastic bare metal instancesall CPU of usage, any metric of any elastic bare metal instanceCPUusagemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of an elastic bare metal instanceCPU of usage, meets the alarm condition triggers an alarm .
CPUaverage usage batch-monitors multipleelastic bare metal instance of average CPUusage, any elastic bare metal instance of average CPUusagemeets the alarm condition triggers an alarm .
disk diskreadIOPS whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected elastic bare metal instancesall disk of readIOPS, any metric of any elastic bare metal instancediskreadIOPSmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of an elastic bare metal instancedisk of readIOPS, meets the alarm condition triggers an alarm .
diskwriteIOPS whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected elastic bare metal instancesall disk of writeIOPS, any metric of any elastic bare metal instancediskwriteIOPSmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of an elastic bare metal instancedisk of writeIOPS, meets the alarm condition triggers an alarm .
diskread speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected elastic bare metal instancesall disk of read speed, any metric of any elastic bare metal instancediskread speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of an elastic bare metal instancedisk of read speed, meets the alarm condition triggers an alarm .
diskwrite speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected elastic bare metal instancesall disk of write speed, any metric of any elastic bare metal instancediskwrite speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of an elastic bare metal instancedisk of write speed, meets the alarm condition triggers an alarm .
diskusedcapacity whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected elastic bare metal instancesall disk of usedcapacity, any metric of any elastic bare metal instancediskusedcapacitymeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of an elastic bare metal instancedisk of usedcapacity, meets the alarm condition triggers an alarm .
diskusedcapacitypercentage whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected elastic bare metal instancesall disk of usedcapacitypercentage, any metric of any elastic bare metal instancediskusedcapacitypercentagemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of an elastic bare metal instancedisk of usedcapacitypercentage, meets the alarm condition triggers an alarm .
diskremainingcapacity whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected elastic bare metal instancesall disk of remainingcapacity, any metric of any elastic bare metal instancediskremainingcapacitymeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of an elastic bare metal instancedisk of remainingcapacity, meets the alarm condition triggers an alarm .
diskremainingcapacitypercentage whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected elastic bare metal instancesall disk of remainingcapacitypercentage, any metric of any elastic bare metal instancediskremainingcapacitypercentagemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of an elastic bare metal instancedisk of remainingcapacitypercentage, meets the alarm condition triggers an alarm .
NIC NICinbound speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected elastic bare metal instancesall NIC of inbound speed, any metric of any elastic bare metal instanceNICinbound speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of an elastic bare metal instanceNIC of inbound speed, meets the alarm condition triggers an alarm .
NICinbound packet count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected elastic bare metal instancesall NIC of inbound packet count, any metric of any elastic bare metal instanceNICinbound packet countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of an elastic bare metal instanceNIC of inbound packet count, meets the alarm condition triggers an alarm .
NICinbound error count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected elastic bare metal instancesall NIC of inbound error count, any metric of any elastic bare metal instanceNICinbound error countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of an elastic bare metal instanceNIC of inbound error count, meets the alarm condition triggers an alarm .
NICoutbound speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected elastic bare metal instancesall NIC of outbound speed, any metric of any elastic bare metal instanceNICoutbound speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of an elastic bare metal instanceNIC of outbound speed, meets the alarm condition triggers an alarm .
NICoutbound packet count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected elastic bare metal instancesall NIC of outbound packet count, any metric of any elastic bare metal instanceNICoutbound packet countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of an elastic bare metal instanceNIC of outbound packet count, meets the alarm condition triggers an alarm .
NICoutbound error count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors the selected elastic bare metal instancesall NIC of outbound error count, any metric of any elastic bare metal instanceNICoutbound error countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified metric of an elastic bare metal instanceNIC of outbound error count, meets the alarm condition triggers an alarm .
memory memorytotal amount batch-monitors multipleelastic bare metal instance of memorytotal amount, any elastic bare metal instance of memorytotal amountmeets the alarm condition triggers an alarm .
remainingmemoryamount batch-monitors multipleelastic bare metal instance of remainingmemoryamount, any elastic bare metal instance of remainingmemoryamountmeets the alarm condition triggers an alarm .
used memoryamount batch-monitors multipleelastic bare metal instance of used memoryamount, any elastic bare metal instance of used memoryamountmeets the alarm condition triggers an alarm .
can use memoryamount batch-monitors multipleelastic bare metal instance of can use memoryamount, any elastic bare metal instance of can use memoryamountmeets the alarm condition triggers an alarm .
remainingmemorypercentage batch-monitors multipleelastic bare metal instance of memoryused percentage, any elastic bare metal instance of memoryused percentagemeets the alarm condition triggers an alarm .
memoryusage batch-monitors multipleelastic bare metal instance of memoryusage, any elastic bare metal instance of memoryusagemeets the alarm condition triggers an alarm .
VPCrouter CPU CPUusage whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VPCrouter CPUusage, any VPCrouter any CPUusagemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VPCrouterspecifiedCPU of usage, meets the alarm condition triggers an alarm .
CPUidle rate whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VPCrouter CPUidle rate, any VPCrouter any CPUidle ratemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VPCrouterspecifiedCPU of idle rate, meets the alarm condition triggers an alarm .
allCPUusage batch-monitors multipleVPCrouter CPUusage, any VPCrouter allCPUusagesummeets the alarm condition triggers an alarm .
Note: percentagesum, can abilityis greater than 100% .
allCPUidle rate batch-monitors multipleVPCrouter CPUidle rate, any VPCrouter allCPUidle ratesummeets the alarm condition triggers an alarm .
Note: percentagesum, can abilityis greater than 100% .
disk diskreadIOPS whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VPCrouter all diskreadIOPS, any VPCrouter any diskreadIOPSmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VPCrouterspecifieddisk of readIOPS, meets the alarm condition triggers an alarm .
alldiskreadIOPS batch-monitors multipleVPCrouter diskreadIOPS, any VPCrouterall disk of readIOPSsummeets the alarm condition triggers an alarm .
diskwriteIOPS whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VPCrouter all diskwriteIOPS, any VPCrouter any diskwriteIOPSmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VPCrouterspecifieddisk of writeIOPS, meets the alarm condition triggers an alarm .
alldiskwriteIOPS batch-monitors multipleVPCrouter diskwriteIOPS, any VPCrouterall disk of writeIOPSsummeets the alarm condition triggers an alarm .
diskread speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VPCrouter all diskread speed, any VPCrouter any diskread speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VPCrouterspecifieddisk of read speed, meets the alarm condition triggers an alarm .
alldiskread speed batch-monitors multipleVPCrouter diskread speed, any VPCrouterall disk of read speedsummeets the alarm condition triggers an alarm .
diskwrite speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VPCrouter all diskwrite speed, any VPCrouter any diskwrite speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VPCrouterspecifieddisk of write speed, meets the alarm condition triggers an alarm .
alldiskwrite speed batch-monitors multipleVPCrouter diskwrite speed, any VPCrouterall disk of write speedsummeets the alarm condition triggers an alarm .
alldiskremainingcapacity(preinstalledagent) batch-monitors multipleVPCrouter alldiskremainingcapacity, any VPCrouteralldiskremainingcapacitymeets the alarm condition triggers an alarm .
alldiskremainingcapacitypercentage(preinstalledagent) batch-monitors multipleVPCrouter alldiskremainingcapacitypercentage, any VPCrouteralldiskremainingcapacitypercentagemeets the alarm condition triggers an alarm .
alldiskusedcapacity(preinstalledagent) batch-monitors multipleVPCrouter alldiskusedcapacity, any VPCrouteralldiskusedcapacitymeets the alarm condition triggers an alarm .
alldiskusedcapacitypercentage(preinstalledagent) batch-monitors multipleVPCrouter alldiskusedcapacitypercentage, any VPCrouteralldiskusedcapacitypercentagemeets the alarm condition triggers an alarm .
diskremainingcapacity(preinstalledagent) whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VPCrouter diskremainingcapacity, any VPCrouter any diskremainingcapacitymeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VPCrouterspecifieddisk of remainingcapacity, meets the alarm condition triggers an alarm .
diskremainingcapacitypercentage(preinstalledagent) whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VPCrouterdiskremainingcapacitypercentage, any VPCrouter any diskremainingcapacitypercentagemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VPCrouterspecifieddisk of remainingcapacitypercentage, meets the alarm condition triggers an alarm .
diskusedcapacity(preinstalledagent) whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VPCrouterdiskusedcapacity, any VPCrouter any diskusedcapacitymeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VPCrouterspecifieddisk of usedcapacity, meets the alarm condition triggers an alarm .
diskusedcapacitypercentage(preinstalledagent) whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VPCrouterdiskusedcapacitypercentage, any VPCrouter any diskusedcapacitypercentagemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VPCrouterspecifieddisk of usedcapacitypercentage, meets the alarm condition triggers an alarm .
NIC NICinbound speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VPCrouter NICinbound speed, any VPCrouter any NICinbound speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VPCrouterspecifiedNIC of inbound speed, meets the alarm condition triggers an alarm .
allNICinbound speed batch-monitors multipleVPCrouter NICinbound speed, any VPCrouterall NICinbound speedsummeets the alarm condition triggers an alarm .
NICinbound packet count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VPCrouter NICinbound packet count, any VPCrouter any NICinbound packet countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VPCrouterspecifiedNIC of inbound packet count, meets the alarm condition triggers an alarm .
allNICinbound packet count batch-monitors multipleVPCrouter NICinbound packet count, any VPCrouterall NICinbound packet countsummeets the alarm condition triggers an alarm .
NICinbound error count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VPCrouter NICinbound error count, any VPCrouter any NICinbound error countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VPCrouterspecifiedNIC of inbound error count, meets the alarm condition triggers an alarm .
allNICinbound error count batch-monitors multipleVPCrouter NICinbound error count, any VPCrouterall NICinbound error countsummeets the alarm condition triggers an alarm .
NICoutbound speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VPCrouter NICoutbound speed, any VPCrouter any NICoutbound speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VPCrouterspecifiedNIC of outbound speed, meets the alarm condition triggers an alarm .
allNICoutbound speed batch-monitors multipleVPCrouter NICoutbound speed, any VPCrouterall NICoutbound speedsummeets the alarm condition triggers an alarm .
NICoutbound packet count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VPCrouter NICoutbound packet count, any VPCrouter any NICoutbound packet countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VPCrouterspecifiedNIC of outbound packet count, meets the alarm condition triggers an alarm .
allNICoutbound packet count batch-monitors multipleVPCrouter NICoutbound packet count, any VPCrouterall NICoutbound packet countsummeets the alarm condition triggers an alarm .
NICoutbound error count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected VPCrouter NICoutbound error count, any VPCrouter any NICoutbound error countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified VPCrouterspecifiedNIC of outbound error count, meets the alarm condition triggers an alarm .
allNICoutbound error count batch-monitors multipleVPCrouter NICoutbound error count, any VPCrouterall NICoutbound error countsummeets the alarm condition triggers an alarm .
memory memoryidlecapacity batch-monitors multipleVPCrouter memoryidlecapacity, any VPCrouter memoryidlecapacitymeets the alarm condition triggers an alarm .
memoryidlepercentage batch-monitors multipleVPCrouter memoryidlepercentage, any VPCrouter memoryidlepercentagemeets the alarm condition triggers an alarm .
memoryused capacity batch-monitors multipleVPCrouter memoryused capacity, any VPCrouter memoryused capacitymeets the alarm condition triggers an alarm .
memoryused percentage batch-monitors multipleVPCrouter memoryused percentage, any VPCrouter memoryused percentagemeets the alarm condition triggers an alarm .
image imagetotal count monitorcloud platformin imagetotal count, meets the alarm condition triggers an alarm .
can use imagetotal count monitorcloud platformin can use imagetotal count, meets the alarm condition triggers an alarm .
can use imagepercentage monitorcloud platformin can use imagepercentage, meets the alarm condition triggers an alarm .
root volumeimagequantity monitorcloud platformin root volumeimagequantity, meets the alarm condition triggers an alarm .
root volumeimagepercentage monitorcloud platformin root volumeimagepercentage, meets the alarm condition triggers an alarm .
data volumeimagequantity monitorcloud platformin data volumeimagequantity, meets the alarm condition triggers an alarm .
data volumeimagepercentage monitorcloud platformin data volumeimagepercentage, meets the alarm condition triggers an alarm .
ISOimagequantity monitorcloud platformin ISOimagequantity, meets the alarm condition triggers an alarm .
ISOimagepercentage monitorcloud platformin ISOimagepercentage, meets the alarm condition triggers an alarm .
image server allimage storagecan use capacity monitorcloud platformin all image server of can use capacity, all image server of can use capacitysummeets the alarm condition triggers an alarm .
allimage storagecan use capacitypercentage monitorcloud platformin all image server of can use capacitypercentage (percentage=all image servercan use capacitysum/all image servercapacitysum), meets the alarm condition triggers an alarm .
image storagecan use capacity batch-monitors multipleimage server of can use capacity, any image server of can use capacitymeets the alarm condition triggers an alarm .
image storagecan use capacitypercentage batch-monitors multipleimage server of can use capacitypercentage, any image server of can use capacitypercentagemeets the alarm condition triggers an alarm .
allimage storageused capacity monitorcloud platformin all image server of used capacity, all image server of used capacitysummeets the alarm condition triggers an alarm .
allimage storageused capacitypercentage monitorcloud platformin all image server of used capacitypercentage (percentage=all image serverused capacitysum/all image servercapacitysum), meets the alarm condition triggers an alarm .
image storageused capacity batch-monitors multipleimage server of used capacity, any image server of used capacitymeets the alarm condition triggers an alarm .
image storageused capacitypercentage batch-monitors multipleimage server of used capacitypercentage, any image server of used capacitypercentagemeets the alarm condition triggers an alarm .
image storagedisabled use capacity monitorcloud platformin image server of reservedcapacityconfiguration, reservedcapacitymeets the alarm condition triggers an alarm .
image storagedisabled use capacitypercentage monitorcloud platformin image server of reservedcapacityconfiguration, any image serverdisabled use capacitypercentage (percentage=reservedcapacity/image servertotalcapacity)meets the alarm condition triggers an alarm .
systemdata directory management nodedata directorydiskidlecapacity monitormanagement nodedata directorydisk of idlecapacity, meets the alarm condition triggers an alarm .
management nodedata directorydiskidle rate monitormanagement nodedata directorydisk of idle rate, meets the alarm condition triggers an alarm .
management nodedata directorydiskused capacity monitormanagement nodedata directorydisk of used capacity, meets the alarm condition triggers an alarm .
management nodedata directorydiskoccupy use rate monitormanagement nodedata directorydisk of occupy use rate, meets the alarm condition triggers an alarm .
host CPU CPUidle rate whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of CPUidle rate, any hostany CPUidle ratemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostspecifiedCPU of idle rate, meets the alarm condition triggers an alarm .
allCPUidle rate batch-monitors multiplehost of CPUidle rate, any host of allCPUidle ratesummeets the alarm condition triggers an alarm .
Note: percentagesum, can abilityis greater than 100% .
CPUusage whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of CPUusage, any hostany CPUusagemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostspecifiedCPU of usage, meets the alarm condition triggers an alarm .
average CPUusage batch-monitors multiplehost of CPUusage, any host of average CPUusagemeets the alarm condition triggers an alarm .
allCPUusage batch-monitors multiplehost of CPUusage, any host of allCPUusagesummeets the alarm condition triggers an alarm .
Note: percentagesum, can abilityis greater than 100% .
allCPUquantity monitorcloud platformin all hostallCPUquantity, CPUquantitysummeets the alarm condition triggers an alarm .
usedCPUquantity monitorcloud platformin all hostused of CPUquantity, usedCPUquantitysummeets the alarm condition triggers an alarm .
disabled use CPUquantity monitorcloud platformin all hostdisabled use CPUquantity, disabled use CPUquantitysummeets the alarm condition triggers an alarm .
usedCPUpercentage monitorcloud platformin all hosttotalbodyusedCPUpercentage (percentage=all hostusedCPUsum/all hostCPUsum), meets the alarm condition triggers an alarm .
disabled use CPUpercentage monitorcloud platformin all hosttotalbodydisabled use CPUpercentage (percentage=all hostdisabled use CPUsum/all hostCPUsum), meets the alarm condition triggers an alarm .
can use CPUquantity monitorcloud platformin all hostcan use CPUquantity, can use CPUquantitysummeets the alarm condition triggers an alarm .
can use CPUpercentage monitorcloud platformin all hosttotalbodycan use CPUpercentage (percentage=all hostcan use CPUsum/all hostCPUsum), meets the alarm condition triggers an alarm .
the hostusedCPUquantity whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of usedCPUquantity, any host of usedCPUquantitymeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified host of usedCPUquantity, meets the alarm condition triggers an alarm .
the hostusedCPUpercentage whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of usedCPUpercentage, any host of usedCPUpercentagemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostusedCPUpercentage, meets the alarm condition triggers an alarm .
the hostcan use CPUquantity whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of can use CPUquantity, any host of can use CPUquantitymeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified host of can use CPUquantity, meets the alarm condition triggers an alarm .
the hostcan use CPUpercentage whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of can use CPUpercentage, any hostcan use CPUpercentagemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified host of can use CPUpercentage, meets the alarm condition triggers an alarm .
CPUtemperature whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of can use CPUtemperature, any hostCPUtemperaturemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostCPUtemperature, meets the alarm condition triggers an alarm .
memory memorynotusagecapacity batch-monitors multiplehost of memorynotusagecapacity, any host of memorynotusagecapacitymeets the alarm condition triggers an alarm .
memorynotusagepercentage batch-monitors multiplehost of memorynotusagepercentage, any host of memorynotusagepercentagemeets the alarm condition triggers an alarm .
memoryusagecapacity batch-monitors multiplehost of memoryusagecapacity, any host of memoryusagecapacitymeets the alarm condition triggers an alarm .
memoryusagepercentage batch-monitors multiplehost of memoryusagepercentage, any host of memoryusagepercentagemeets the alarm condition triggers an alarm .
memorycapacity monitorcloud platformin all host of memorycapacity, all host of memorycapacitysummeets the alarm condition triggers an alarm .
usedmemorycapacity monitorcloud platformin all host of usedmemorycapacity, all host of usedmemorycapacitysummeets the alarm condition triggers an alarm .
usedmemorypercentage monitorcloud platformin all host of usedmemorycapacity, all host of totalbodyusedmemorypercentage (percentage=all hostusedmemorycapacitysum/all hostmemorycapacitysum)meets the alarm condition triggers an alarm .
disabled use memorycapacity monitorcloud platformin hostreservedmemoryconfiguration, reservedmemorycapacitymeets the alarm condition triggers an alarm .
disabled use memorycapacitypercentage monitorcloud platformin hostreservedmemoryconfiguration, any hostreservedmemorycapacitypercentage (percentage=hostreservedmemory/hosttotalmemory)meets the alarm condition triggers an alarm .
remainingmemorycapacity monitorcloud platformin all host of remainingmemorycapacity, all host of remainingmemorycapacitysummeets the alarm condition triggers an alarm .
remainingmemorycapacitypercentage monitorcloud platformin all host of remainingmemorycapacity, all host of totalbodyremainingmemorycapacitypercentage (percentage=totalremainingmemorycapacity/totalmemorycapacity)meets the alarm condition triggers an alarm .
the hostused memorycapacity batch-monitors multiplehost of used memorycapacity, any host of used memorycapacitymeets the alarm condition triggers an alarm .
the hostused memorycapacitypercentage batch-monitors multiplehost of used memorycapacitypercentage, any host of used memorycapacitypercentagemeets the alarm condition triggers an alarm .
the hostcan use memorycapacity batch-monitors multiplehost of can use memorycapacity, any host of can use memorycapacitymeets the alarm condition triggers an alarm .
the hostcan use memorycapacitypercentage batch-monitors multiplehost of can use memorycapacitypercentage, any host of can use memorycapacitypercentagemeets the alarm condition triggers an alarm .
disk diskreadIOPS whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of diskreadIOPS, any hostany diskreadIOPSmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostspecifieddisk of readIOPS, meets the alarm condition triggers an alarm .
alldiskreadIOPS batch-monitors multiplehost of diskreadIOPS, any host of all diskreadIOPSsummeets the alarm condition triggers an alarm .
diskwriteIOPS whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of all diskwriteIOPS, any hostany diskwriteIOPSmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostspecifieddisk of writeIOPS, meets the alarm condition triggers an alarm .
alldiskwriteIOPS batch-monitors multiplehost of diskwriteIOPS, any hostall disk of writeIOPSsummeets the alarm condition triggers an alarm .
diskread speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of all diskread speed, any hostany diskread speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostspecifieddisk of read speed, meets the alarm condition triggers an alarm .
alldiskread speed batch-monitors multiplehost of diskread speed, any hostall disk of read speedsummeets the alarm condition triggers an alarm .
diskwrite speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of all diskwrite speed, any hostany diskwrite speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostspecifieddisk of write speed, meets the alarm condition triggers an alarm .
alldiskwrite speed batch-monitors multiplehost of diskwrite speed, any hostall disk of write speedsummeets the alarm condition triggers an alarm .
alldiskremainingcapacity batch-monitors multiplehost of diskremainingcapacity, any hostall disk of remainingcapacitysummeets the alarm condition triggers an alarm .
alldiskremainingcapacitypercentage batch-monitors multiplehost of diskremainingcapacitypercentage, any hostall diskremainingcapacitypercentage (percentage=all diskremainingcapacitysum/all diskcapacitysum)meets the alarm condition triggers an alarm .
alldiskusedcapacity batch-monitors multiplehost of diskusedcapacity, any hostall disk of usedcapacitysummeets the alarm condition triggers an alarm .
alldiskusedcapacitypercentage batch-monitors multiplehost of diskusedcapacitypercentage, any hostall diskusedcapacitypercentage (percentage=all diskusedcapacitysum/all diskcapacitysum)meets the alarm condition triggers an alarm .
diskcapacity whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of diskcapacity, any hostany diskcapacitymeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostspecifieddisk of capacity, meets the alarm condition triggers an alarm .
diskremainingcapacitypercentage whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of diskremainingcapacitypercentage, any hostany diskremainingcapacitypercentagemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostspecifieddisk of remainingcapacitypercentage, meets the alarm condition triggers an alarm .
diskusedcapacity whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of diskusedcapacity, any hostany diskusedcapacitymeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostspecifieddisk of usedcapacity, meets the alarm condition triggers an alarm .
diskusedcapacitypercentage whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of diskusedcapacitypercentage, any hostany diskusedcapacitypercentagemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostspecifieddisk of usedcapacitypercentage, meets the alarm condition triggers an alarm .
root diskusage batch-monitors multiplehost of root diskusage, any host of root diskusagemeets the alarm condition triggers an alarm .
root diskusagecapacity batch-monitors multiplehost of root diskusagecapacity, any host of root diskusagecapacitymeets the alarm condition triggers an alarm .
XFSfile system fragmentation levelpercentage whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of XFSfile system fragmentation levelpercentage, any host of XFSfile system fragmentation levelpercentagemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostXFSfilesystem of fragmentation levelpercentage, meets the alarm condition triggers an alarm .
SSDtemperature whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of SSDdisktemperature, any hostany SSDdisktemperaturemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostspecifiedSSDdisktemperature, meets the alarm condition triggers an alarm .
SSDremaining life whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of SSDdiskremaining life, any hostany SSDdiskremaining lifemeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostspecifiedSSDdiskremaining life, meets the alarm condition triggers an alarm .
NIC NICinbound speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of NICinbound speed, any hostany NICinbound speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostspecifiedNIC of inbound speed, meets the alarm condition triggers an alarm .
allNICinbound speed batch-monitors multiplehost of NICinbound speed, any hostall NICinbound speedsummeets the alarm condition triggers an alarm .
NICinbound packet count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of NICinbound packet count, any hostany NICinbound packet countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostspecifiedNIC of inbound packet count, meets the alarm condition triggers an alarm .
allNICinbound packet count batch-monitors multiplehost of NICinbound packet count, any hostall NICinbound packet countsummeets the alarm condition triggers an alarm .
NICinbound error count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of NICinbound error count, any hostany NICinbound error countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostspecifiedNIC of inbound error count, meets the alarm condition triggers an alarm .
allNICinbound error count batch-monitors multiplehost of NICinbound error count, any hostall NICinbound error countsummeets the alarm condition triggers an alarm .
NICoutbound speed whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of NICoutbound speed, any hostany NICoutbound speedmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostspecifiedNIC of outbound speed, meets the alarm condition triggers an alarm .
allNICoutbound speed batch-monitors multiplehost of NICoutbound speed, any hostall NICoutbound speedsummeets the alarm condition triggers an alarm .
NICoutbound packet count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of NICoutbound packet count, any hostany NICoutbound packet countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostspecifiedNIC of outbound packet count, meets the alarm condition triggers an alarm .
allNICoutbound packet count batch-monitors multiplehost of NICoutbound packet count, any hostall NICoutbound packet countsummeets the alarm condition triggers an alarm .
NICoutbound error count whether a configuration is specified, uses different resource monitoring granularities .can as neededselect :
  • no configuration is specified: monitors selected host of NICoutbound error count, any hostany NICoutbound error countmeets the alarm condition triggers an alarm .
  • a configuration is specified: monitors a specified hostspecifiedNIC of outbound error count, meets the alarm condition triggers an alarm .
allNICoutbound error count batch-monitors multiplehost of NICoutbound error count, any hostall NICoutbound error countsummeets the alarm condition triggers an alarm .
hostConntrackconnectioncount batch-monitors multiplehost of Conntrackconnectioncount, any host of Conntrackconnectioncountmeets the alarm condition triggers an alarm .
hostConntrackusedpercentage batch-monitors multiplehost of Conntrackusedamount, any host of Conntrackusedpercentagemeets the alarm condition triggers an alarm .
other hostquantity monitorcloud platformin hostquantity, hosttotal countmeets the alarm condition triggers an alarm .
connectedhostquantity monitorcloud platformin hostquantity, connectedhostquantitymeets the alarm condition triggers an alarm .
connectedhostpercentage monitorcloud platformin hostquantity, connectedhostpercentage (percentage=connectedhostquantity/hosttotal count)meets the alarm condition triggers an alarm .
disconnectedhostquantity monitorcloud platformin hostquantity, disconnectedhostquantitymeets the alarm condition triggers an alarm .
disconnectedhostpercentage monitorcloud platformin hostquantity, disconnectedhostpercentage (percentage=disconnectedhostquantity/hosttotal count)meets the alarm condition triggers an alarm .
elastic bare metal gateway node elastic bare metal gateway nodequantity monitorcloud platformin elastic bare metal gateway nodequantity, elastic bare metal gateway nodetotal countmeets the alarm condition triggers an alarm .
connectedelastic bare metal gateway nodequantity monitorcloud platformin elastic bare metal gateway nodequantity, connectedelastic bare metal gateway nodequantitymeets the alarm condition triggers an alarm .
connectedelastic bare metal gateway nodepercentage monitorcloud platformin elastic bare metal gateway nodequantity, connectedelastic bare metal gateway nodepercentage (percentage=connectedelastic bare metal gateway nodequantity/elastic bare metal gateway nodetotal count)meets the alarm condition triggers an alarm .
disconnectedelastic bare metal gateway nodequantity monitorcloud platformin elastic bare metal gateway nodequantity, disconnectedelastic bare metal gateway nodequantitymeets the alarm condition triggers an alarm .
disconnectedelastic bare metal gateway nodepercentage monitorcloud platformin elastic bare metal gateway nodequantity, disconnectedelastic bare metal gateway nodepercentage (percentage=disconnectedelastic bare metal gateway nodequantity/elastic bare metal gateway nodetotal count)meets the alarm condition triggers an alarm .
L3network allcan use IPcount (IPv4) monitorcloud platformin all IPv4typeL3network of IPaddress count, all L3network of can use IPcountsummeets the alarm condition triggers an alarm .
allcan use IPpercentage (IPv4) monitorcloud platformin all IPv4typeL3network of IPaddress count, allcan use IPpercentage (allcan use IPpercentage=all L3networkcan use IPtotal count/all L3networkIPtotal count)meets the alarm condition triggers an alarm .
allused IPcount (IPv4) monitorcloud platformin all IPv4typeL3network of IPaddress count, all L3network of used IPcountsummeets the alarm condition triggers an alarm .
allused IPpercentage (IPv4) monitorcloud platformin all IPv4typeL3network of IPaddress count, allused IPpercentage (allused IPpercentage=all L3networkused IPtotal count/all L3networkIPtotal count)meets the alarm condition triggers an alarm .
alldisabled use IPcount (IPv4) monitorcloud platformin all IPv4typeL3network of IPaddress count, all L3network of disabled use IPcountsummeets the alarm condition triggers an alarm .
alldisabled use IPpercentage (IPv4) monitorcloud platformin all IPv4typeL3network of IPaddress count, alldisabled use IPpercentage (alldisabled use IPpercentage=all L3networkdisabled use IPtotal count/all L3networkIPtotal count)meets the alarm condition triggers an alarm .
can use IPcount (IPv4) batch-monitors multipleIPv4typeL3network of IPaddress count, any L3network of can use IPcountmeets the alarm condition triggers an alarm .
can use IPpercentage (IPv4) batch-monitors multipleIPv4typeL3network of IPaddress count, any L3network of can use IPpercentagemeets the alarm condition triggers an alarm .
used IPcount (IPv4) batch-monitors multipleIPv4typeL3network of IPaddress count, any L3network of used IPcountmeets the alarm condition triggers an alarm .
used IPpercentage (IPv4) batch-monitors multipleIPv4typeL3network of IPaddress count, any L3network of used IPpercentagemeets the alarm condition triggers an alarm .
volume volumetotal count monitorcloud platformin root volume and data volumequantity, root volume and data volumequantitysummeets the alarm condition triggers an alarm .
root volumetotal count monitorcloud platformin root volumequantity, root volumetotal countmeets the alarm condition triggers an alarm .
root volumepercentage monitorcloud platformin root volumepercentage (percentage=root volumequantity/root volume and data volumequantitysum), meets the alarm condition triggers an alarm .
data volumetotal count monitorcloud platformin data volumequantity, data volumetotal countmeets the alarm condition triggers an alarm .
data volumepercentage monitorcloud platformin data volumepercentage (percentage=data volumequantity/root volume and data volumequantitysum), meets the alarm condition triggers an alarm .
can use data volumetotal count monitorcloud platformin data volumestatus, can use data volumequantitymeets the alarm condition triggers an alarm .
can use data volumepercentage monitorcloud platformin data volumestatus, can use data volumepercentage (percentage=can use data volumequantity/data volumetotal amount)meets the alarm condition triggers an alarm .
volume snapshottotal count monitorcloud platformin volume snapshot (data volume snapshot+root volume snapshot)quantity, volume snapshottotal countmeets the alarm condition triggers an alarm .
root volume snapshottotal count monitorcloud platformin root volume snapshotquantity, root volume snapshottotal countmeets the alarm condition triggers an alarm .
root volume snapshotpercentage monitorcloud platformin root volume snapshotpercentage (percentage=root volume snapshottotal count/root volume snapshot and data volume snapshotsum), meets the alarm condition triggers an alarm .
data volume snapshottotal count monitorcloud platformin data volume snapshotquantity, data volume snapshottotal countmeets the alarm condition triggers an alarm .
data volume snapshotpercentage monitorcloud platformin all data volume snapshotpercentage (percentage=data volume snapshottotal count/root volume snapshot and data volume snapshotsum), any data volume snapshotpercentagemeets the alarm condition triggers an alarm .
volumeusagecapacitypercentage monitorcloud platformin all volumeusagecapacitypercentage (percentage=usagecapacity/volumetotalcapacity), any volumeusagecapacitypercentagemeets the alarm condition triggers an alarm .
Note: thick provisioningtypevolume (exampleAs shown in : Shared Blockprimary storage on thick provisioningtype of volume) of usagecapacitypercentageas100%, settingsthis alarmwillstandalonethen trigger .
(100GBandby on )fragmentation level (Extenttotal count) monitorcloud platformin all capacityexceeds100GBvolume of fragmentation level, any volumefragmentation level of fragmentation level (Extenttotal count)meets the alarm condition triggers an alarm .
Note: usagethisalarm itemNote thatby under status:
  • systemdefaultXFSfile system fragmentation level of monitorcountdatasamplingtimeintervalas12hour;
  • match carefullythe sampling period, settingsproperly of alarmthresholdfor time .
virtualIP under rownetworktraffic batch-monitors multiplevirtualIP of under rownetworktraffic, any virtualIP of under rownetworktrafficmeets the alarm condition triggers an alarm .
under rownetworkpacket count batch-monitors multiplevirtualIP of under rownetworkpacket count, any virtualIP of under rownetworkpacket countmeets the alarm condition triggers an alarm .
on rownetworktraffic batch-monitors multiplevirtualIP of on rownetworktraffic, any virtualIP of on rownetworktrafficmeets the alarm condition triggers an alarm .
on rownetworkpacket count batch-monitors multiplevirtualIP of on rownetworkpacket count, any virtualIP of on rownetworkpacket countmeets the alarm condition triggers an alarm .
primary storage allcapacity monitorcloud platformin all primary storagecapacity, all primary storagecapacitysummeets the alarm condition triggers an alarm .
allcan use capacity monitorcloud platformin all primary storagecan use capacity, all primary storagecan use capacitysummeets the alarm condition triggers an alarm .
allcan use capacitypercentage monitorcloud platformin all primary storagecan use capacitypercentage (percentage=all primary storagecan use capacitysum/all primary storagecapacitysum), meets the alarm condition triggers an alarm .
allused capacity monitorcloud platformin all primary storageused capacity, all primary storageused capacitysummeets the alarm condition triggers an alarm .
allused capacitypercentage monitorcloud platformin all primary storageused capacitypercentage (percentage=all primary storageused capacitysum/all primary storagecapacitysum), meets the alarm condition triggers an alarm .
alldisabled use capacity monitorcloud platformin primary storagereservedcapacityconfiguration, all primary storagereservedcapacitysummeets the alarm condition triggers an alarm .
alldisabled use capacitypercentage monitorcloud platformin all primary storagereservedcapacityconfiguration, primary storagealldisabled use capacitypercentage (percentage=all primary storagereservedcapacitysum/all primary storagecapacitysum)meets the alarm condition triggers an alarm .
the primary storagecan use capacity batch-monitors multipleprimary storage of can use capacity, any primary storage of can use capacitymeets the alarm condition triggers an alarm .
the primary storagecan use capacitypercentage batch-monitors multipleprimary storage of can use capacitypercentage (percentage=can use capacity/primary storagetotalcapacity), any primary storage of can use capacitypercentagemeets the alarm condition triggers an alarm .
the primary storageused capacity batch-monitors multipleprimary storage of used capacity, any primary storage of used capacitymeets the alarm condition triggers an alarm .
the primary storageused capacitypercentage batch-monitors multipleprimary storage of used capacitypercentage (percentage=used capacity/primary storagetotalcapacity), any primary storage of used capacitypercentagemeets the alarm condition triggers an alarm .
the primary storagecan use physical capacity batch-monitors multipleprimary storage of can use physical capacity, any primary storage of can use physical capacitymeets the alarm condition triggers an alarm .
the primary storagecan use physical capacitypercentage batch-monitors multipleprimary storage of can use physical capacitypercentage (percentage=can use physical capacity/primary storagetotalphysical capacity), any primary storage of can use physical capacitypercentagemeets the alarm condition triggers an alarm .
the primary storageused physical capacity batch-monitors multipleprimary storage of used physical capacity, any primary storage of used physical capacitymeets the alarm condition triggers an alarm .
the primary storageused physical capacitypercentage batch-monitors multipleprimary storage of used physical capacitypercentage (percentage=used physical capacity/primary storagetotalphysical capacity), any primary storage of used physical capacitypercentagemeets the alarm condition triggers an alarm .
the primary storageroot volumequantity batch-monitors multipleprimary storagein of root volumequantity, any primary storagein of root volumequantitymeets the alarm condition triggers an alarm .
the primary storagedata volumequantity batch-monitors multipleprimary storagein of data volumequantity, any primary storagein of data volumequantitymeets the alarm condition triggers an alarm .
the primary storagesnapshotquantity batch-monitors multipleprimary storagein of snapshotquantity, any primary storagein of snapshotquantitymeets the alarm condition triggers an alarm .
Cephstorage poolcan use capacitypercentage batch-monitors multipleprimary storagein of Cephstorage poolcan use capacitypercentage, any primary storagein of Cephstorage poolcan use capacitymeets the alarm condition triggers an alarm .
Cephstorage poolused capacitypercentage batch-monitors multipleprimary storagein of Cephstorage poolused capacitypercentage, any primary storagein of Cephstorage poolused capacitymeets the alarm condition triggers an alarm .
listener sessionused quantity batch-monitors multiplelistener of sessionquantity, any listener of sessionused quantitymeets the alarm condition triggers an alarm .
sessionused percentage batch-monitors multiplelistener of sessionused percentage (percentage=sessionused quantity/sessiontotal amount), any listener of sessionused percentagemeets the alarm condition triggers an alarm .
checknot to healthy of backendservicedevice batch-monitors multiplelistener of backendservicedevicegroup in of backendservicedevicestatus, any listener of backendservicedevicegroup in has not healthy of backendservicedevice triggers an alarm .
management node arbiterIPnot can reach monitormultiple management nodesarbiterIPwhethercan reach, whenarbiterIPnot can reachwhen triggers an alarm .
dual management nodesdatabase is not synchronized monitordual management nodescountdatabasestatus, whencountdatabaseabnormal or dual management nodesdatabase is not synchronizedwhen triggers an alarm .
projectresource (requiresenterprisemanagemodulelicense) computeresource VM instancequantity quota usagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project VM instancequantity quota usagepercentage, any project VM instancequantity quota usagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project VM instancequantity quota usagepercentage, any project VM instancequantity quota usagepercentagereaches the threshold triggers an alarm .
running in VM instancequantity quota usagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project running in VM instancequantity quota usagepercentage, any project running in VM instancequantity quota usagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project running in VM instancequantity quota usagepercentage, any project running in VM instancequantity quota usagepercentagereaches the threshold triggers an alarm .
CPUquantity quota usagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project CPUquantity quota usagepercentage, any project CPUquantity quota usagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project CPUquantity quota usagepercentage, any project CPUquantity quota usagepercentagereaches the threshold triggers an alarm .
memoryquotausagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project memoryquotausagepercentage, any project memoryquotausagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project memoryquotausagepercentage, any project memoryquotausagepercentagereaches the threshold triggers an alarm .
GPUdevicequantity quota usagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project GPUdevicequantity quota usagepercentage, any project GPUdevicequantity quota usagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project GPUdevicequantity quota usagepercentage, any project GPUdevicequantity quota usagepercentagereaches the threshold triggers an alarm .
affinity and groupquantity quota usagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project affinity and groupquantity quota usagepercentage, any project affinity and groupquantity quota usagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project affinity and groupquantity quota usagepercentage, any project affinity and groupquantity quota usagepercentagereaches the threshold triggers an alarm .
storageresource volume snapshotquantity quota usagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project volume snapshotquantity quota usagepercentage, any project volume snapshotquantity quota usagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project volume snapshotquantity quota usagepercentage, any project volume snapshotquantity quota usagepercentagereaches the threshold triggers an alarm .
data volumequantity quota usagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project data volumequantity quota usagepercentage, any project data volumequantity quota usagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project data volumequantity quota usagepercentage, any project data volumequantity quota usagepercentagereaches the threshold triggers an alarm .
can use storagecapacityquotausagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project can use storagecapacityquotausagepercentage, any project can use storagecapacityquotausagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project can use storagecapacityquotausagepercentage, any project can use storagecapacityquotausagepercentagereaches the threshold triggers an alarm .
imagequantity quota usagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project imagequantity quota usagepercentage, any project imagequantity quota usagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project imagequantity quota usagepercentage, any project imagequantity quota usagepercentagereaches the threshold triggers an alarm .
all imagecapacityquotausagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project all imagecapacityquotausagepercentage, any project all imagecapacityquotausagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project all imagecapacityquotausagepercentage, any project all imagecapacityquotausagepercentagereaches the threshold triggers an alarm .
can use backupcapacityquotausagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project can use backupcapacityquotausagepercentage, any project can use backupcapacityquotausagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project can use backupcapacityquotausagepercentage, any project can use backupcapacityquotausagepercentagereaches the threshold triggers an alarm .
backupquantity quota usagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project backupquantity quota usagepercentage, any project backupquantity quota usagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project backupquantity quota usagepercentage, any project backupquantity quota usagepercentagereaches the threshold triggers an alarm .
networkresource VXLANnetworkquantity quota usagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project VXLANnetworkquantity quota usagepercentage, any project VXLANnetworkquantity quota usagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project VXLANnetworkquantity quota usagepercentage, any project VXLANnetworkquantity quota usagepercentagereaches the threshold triggers an alarm .
L3networkquantity quota usagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project L3networkquantity quota usagepercentage, any project L3networkquantity quota usagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project L3networkquantity quota usagepercentage, any project L3networkquantity quota usagepercentagereaches the threshold triggers an alarm .
securegroupquantity quota usagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project securegroupquantity quota usagepercentage, any project securegroupquantity quota usagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project securegroupquantity quota usagepercentage, any project securegroupquantity quota usagepercentagereaches the threshold triggers an alarm .
virtualIPquantity quota usagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project virtualIPquantity quota usagepercentage, any project virtualIPquantity quota usagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project virtualIPquantity quota usagepercentage, any project virtualIPquantity quota usagepercentagereaches the threshold triggers an alarm .
elastic performanceIPquantity quota usagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project elastic performanceIPquantity quota usagepercentage, any project elastic performanceIPquantity quota usagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project elastic performanceIPquantity quota usagepercentage, any project elastic performanceIPquantity quota usagepercentagereaches the threshold triggers an alarm .
portforwardquantity quota usagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project portforwardquantity quota usagepercentage, any project portforwardquantity quota usagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project portforwardquantity quota usagepercentage, any project portforwardquantity quota usagepercentagereaches the threshold triggers an alarm .
load balancingdevicequantity quota usagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project load balancingdevicequantity quota usagepercentage, any project load balancingdevicequantity quota usagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project load balancingdevicequantity quota usagepercentage, any project load balancingdevicequantity quota usagepercentagereaches the threshold triggers an alarm .
listenerquantity quota usagepercentage alarm scopeSupports All Resources and Multiple Resources, can as neededselect :
  • All Resources: monitorcloud platformin all project listenerquantity quota usagepercentage, any project listenerquantity quota usagepercentagereaches the threshold triggers an alarm .
  • Multiple Resources: monitors selected project listenerquantity quota usagepercentage, any project listenerquantity quota usagepercentagereaches the threshold triggers an alarm .
CDPtask (requiresfor data protectionCDPmodulelicense) CDPtaskused capacityoccupyplannedcapacitypercentage monitorcloud platformin all CDPtaskused capacityoccupyplannedcapacity of percentage, any CDPtask of used capacity and plannedcapacity of occupyratioreaches the threshold triggers an alarm .
RPOoffsettime monitorcloud platformin all CDPtask of RPOoffsettime, any CDPtask of RPOoffsettimereaches the threshold triggers an alarm .

Event Alarm Items

Default Alarm Items

resource type alarm item description
VM instance VM instancefault Monitors cloud platformin all running in of VM instancestatus, any running in of VM instancehas fault triggers an alarm .
Note: VM instancerequires installation oflatestNewly version of GuestToolstool, andthe toolneeds to is inrunningstatus .
VM instancestays in in shutdownstatus
  • Monitors cloud platformall VM instance .
  • any VM instancestays in in shutdownstatus, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
VM instanceOn hostHAstarts
  • Monitors cloud platformall VM instance .
  • any VM instanceOn hostHAstarts, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
host hostconnected
  • Monitors cloud platformall host .
  • any host from disconnectedstatusrestores connection, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
hostgo tomaintenance modetriggerVM instancemigration fails
  • Monitors cloud platformall host .
  • any hostgo tomaintenance modetriggerVM instancemigration fails, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
hostdisconnected
  • Monitors cloud platformall host .
  • any hostdisconnected, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
hostNICdisconnected
  • Monitors cloud platformall hostNIC .
  • any hostNICdisconnected, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
hostNICconnected
  • Monitors cloud platformall hostNIC .
  • any hostNIC from disconnectedstatusrestores connection, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
hostmount path error
  • Monitors cloud platformall host .
  • any hostmount path error, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
host on is found with not managed by the system of VM instance
  • Monitors cloud platformall host .
  • any host on is found with not managed by the system of VM instance, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
CPUstatusabnormal
  • Monitors cloud platformall host .
  • any host on is found with statusabnormal of CPU, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
memorystatusabnormal
  • Monitors cloud platformall host .
  • any host on is found with statusabnormal of memory, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
memoryECCalarm
  • Monitors cloud platformall host .
  • any host on foundmemoryECCalarm, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
diskstatusabnormal
  • Monitors cloud platformall host .
  • any host on is found with physical disk of readystatusabnormal, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
diskremoved
  • Monitors cloud platformall host .
  • any host on is found with diskremoved, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
diskinsert
  • Monitors cloud platformall host .
  • any host on is found with diskinsert, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
fanstatusabnormal
  • Monitors cloud platformall host .
  • any host on is found with statuscheckabnormal of fan, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
image server image serverconnected
  • Monitors cloud platformall image server .
  • any image server from disconnectedstatusrestores connection, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
image serverdisconnected
  • Monitors cloud platformall image server .
  • any image serverdisconnected, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
primary storage primary storageconnected
  • Monitors cloud platformall primary storage .
  • any primary storage from disconnectedstatusrestores connection, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
primary storagedisconnected
  • Monitors cloud platformall primary storage .
  • any primary storagedisconnected, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
primary storage to hostconnectionstatuscheck failed
  • Monitors cloud platformall primary storage .
  • any primary storage to hostconnectionstatuscheck failed, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
management node management nodeconnected
  • Monitors cloud platformall management node .
  • any management node from disconnectedstatusrestores connection, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
management nodedisconnected
  • Monitors cloud platformall management node .
  • any management nodedisconnected, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
VPCrouter VPCrouterconnected
  • Monitors cloud platformall VPCrouter .
  • any VPCrouter from disconnectedstatusrestores connection, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
VPCrouterdisconnected
  • Monitors cloud platformall VPCrouter .
  • any VPCrouterdisconnected, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
routeractive/standbyswitch
  • Monitors cloud platformall VPCrouter .
  • any VPCrouteractive/standbyswitch, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
VPCrouterdiskspace occupied byabnormalfileoccupy use
  • Monitors cloud platformall VPCrouter .
  • any VPCrouterhas exceeds100 MB of single file triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
router enabledstatuschanges toaspausedstop
  • Monitors cloud platformall VPCrouter .
  • any VPCrouter enabledstatuschanges toaspausedstop triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
notificationforobject SMS sending failed
  • Monitors cloud platformall SMS receiver .
  • any SMS receiver cannot receive SMS alarm messages, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
CDPtask (requiresfor data protectionCDPmodulelicense) CDPtaskstatusabnormalswitch
  • monitorcloud platformin all CDPtask of taskstatus .
  • any CDPtaskstatusoccursabnormalswitch triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
Note: triggerCDPtaskstatusabnormalswitch of reason:
  • CDPcountdataoccupy use capacityreach to plannedcapacity on limit
  • CDPtasklocated On of backupservicedevicedisconnected
load balancer instance load balancer instancedisconnected
  • Monitors cloud platformall load balancer instance .
  • any load balancer instancedisconnected, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .
load balancer instanceconnected
  • Monitors cloud platformall load balancer instance .
  • any load balancer instance from disconnectedstatusrestores connection, triggers an alarm .
  • By default, platform message notification is triggered, after a receiver is bound, can alarm messages can be received through the receiver .

customalarm item

resource type alarm item description
VM instance VM instanceOn hostHAstarts monitorcloud platformin all NeverStopVM instance, any NeverStopVM instanceOn hostHAstarts triggers an alarm .
VM instanceOn host on of statuschanges monitorcloud platformin all VM instanceOn host on of status, any VM instance of statuschanges triggers an alarm .
Note: VM instanceabnormal of statuschanges to change can willtriggeralarm, normal of start, stop, and power operationsoperationnot willtriggeralarm .
VM instancestays in in shutdownstatus monitorcloud platformin all VM instancestatus, any VM instancelongtime (about10minutes)is inin shutdownstatus triggers an alarm .
VM instancefault monitorcloud platformin all running in of VM instancestatus, any running in of VM instancehas fault triggers an alarm .
Note: VM instancerequires installation oflatestNewly version of GuestToolstool, andthe toolneeds to is inrunningstatus .
VPCrouter VPCrouterdisconnected monitorcloud platformin all VPCrouter readystatus, any routerdisconnected triggers an alarm .
VPCrouterconnected monitorcloud platformin all VPCrouter readystatus, any VPCrouterconnectionafter triggers an alarm .
routeractive/standbyswitch monitorcloud platformhighcan use groupin of VPCrouterstatus, any highcan use groupin of VPCrouteractive/standby switchover occursswitch triggers an alarm .
VPCrouterdiskspace occupied byabnormalfileoccupy use monitorcloud platformall VPCrouterin of diskoccupy use status, any VPCrouterhas exceeds100 MB of single file triggers an alarm .
load balancing load balancer instancedisconnected monitorcloud platformin all load balancer instance of readystatus, any load balancer instancedisconnected triggers an alarm .
load balancer instanceconnected monitorcloud platformin all load balancer instance of readystatus, any load balancer instanceconnectionafter triggers an alarm .
image server image serverdisconnected monitorcloud platformin all image server of readystatus, any image serverdisconnected triggers an alarm .
image serverconnected monitorcloud platformin all image server of readystatus, any image serverconnectionafter triggers an alarm .
management node management nodedisconnected monitorcloud platformin all management node of readystatus, any management nodedisconnected triggers an alarm .
management nodeconnected monitorcloud platformin all management node of readystatus, any management nodeconnectionafter triggers an alarm .
host host on is found with not managed by the system of VM instance monitorcloud platformin all host on of VM instancestatus, any actualexampleVM instancenotiscountdatabaserecord triggers an alarm .
hostdisconnected monitorcloud platformin all host of readystatus, any hostdisconnected triggers an alarm .
hostconnected monitorcloud platformin all host of readystatus, any hostconnectionafter triggers an alarm .
hostNICdisconnected monitorcloud platformin all is inconnectedstatus of host of NICreadystatus, any hostNICdisconnected triggers an alarm .
hostNICconnected monitorcloud platformin all is inconnectedstatus of host of NICreadystatus, any hostNICrecoverednormalconnection triggers an alarm .
CPUstatusabnormal monitorcloud platformin all is inconnectedstatus of host of CPUstatus, any hostCPUstatusabnormal triggers an alarm .
memorystatusabnormal monitorcloud platformin all is inconnectedstatus of host of memorystatus, any hostmemorystatusabnormal triggers an alarm .
memoryECCalarm monitorcloud platformin all is inconnectedstatus of hostECCalarm, any hostfoundmemoryECCalarm triggers an alarm .
diskstatusabnormal monitorcloud platformin all is inconnectedstatus of host of diskreadystatus, any hostdiskconfigurationstatuscheckabnormal triggers an alarm .
diskremoved monitorcloud platformin all is inconnectedstatus of host of diskconnectionstatus, any hostdiskremoved triggers an alarm .
diskinsert monitorcloud platformin all is inconnectedstatus of host of diskconnectionstatus, any hostdiskinsert triggers an alarm .
fanstatusabnormal monitorcloud platformin all is inconnectedstatus of host of fanstatus, any hostfanstatuscheckabnormal triggers an alarm .
primary storage primary storage to hostconnectionstatuscheck failed monitorcloud platformin primary storage and host of connectionstatus, whencloud platformnotobtain to primary storage and host of connectionstatuswhen, triggers an alarm .
primary storagedisconnected monitorcloud platformin all primary storage of readystatus, any primary storagedisconnected triggers an alarm .
primary storageconnected monitorcloud platformin all primary storage of readystatus, any primary storageconnectionafter triggers an alarm .
hostmount path error monitorcloud platformin specifiedprimary storage (NFS/SharedMountPoint/AliyunNAS) of URL (hostmount path), whenany primary storage of URLcannot be obtained, triggers an alarm .
vCenter vCenterhosttimeabnormal monitormanagedvCenterenvironmentin all hosttime and cloud platformsystemtimewhether they are consistent, any vCenterhosttimeabnormal triggers an alarm .
vCenterevent message displaymanagedvCenter of event message, any vCentergenerated of event messageallcan through alarms of displayed .
backuptask task resultfailed monitorcloud platformin all backuptask of executestatus, any backuptaskafter failure triggers an alarm .
projectresource (requiresenterprisemanagemodulelicense) projectreclaimed monitorcloud platformin all projectstatus, any projectreclaimed triggers an alarm .
HA hostgo tomaintenance modetriggerVM instancemigration fails monitorcloud platformin VM instance of migrationstatus, any non-localstorage of hostgo tomaintenance modetriggerVM instancemigration fails triggers an alarm .
CDPtask (requiresfor data protectionCDPmodulelicense) CDPtaskfailed monitorcloud platformin all CDPtask of executestatus, any CDPtaskafter failure triggers an alarm .
CDPtaskstatusabnormalswitch monitorcloud platformin all CDPtask of taskstatus, any CDPtaskstatusoccursabnormalswitch triggers an alarm .
Note: triggerCDPtaskstatusabnormalswitch of reason:
  • CDPcountdataoccupy use capacityreach to plannedcapacity on limit
  • CDPtasklocated On of backupservicedevicedisconnected
User Guide | 2.4.8.38 | Flagship Edition · HCI | ZStack Resource Center