Sites and Fabric

Organize sites and compute clusters, configure host networks and transport zones, and prepare infrastructure for workload networks.

After connecting a compute manager, you can organize discovered clusters and hosts in ZNS, configure common network parameters and transport zones, and connect hosts to prepare infrastructure for workload networks. Prepare edge or inter-site resources as needed for external connectivity or connections between sites.

Resource Organization and Configuration Process

Sites organize compute resources by physical location, failure domain, and network conditions within each site. Resources at the same physical site can come from one or more ZSphere environments. Prepare the site's network infrastructure according to its member clusters.

Configuration Activity Purpose and Dependencies
Organize Sites and Clusters Determine the site's compute resource scope, then use Create a Site and Associate Clusters to establish cluster membership. This determines the scope for subsequent host selection and network configuration.
Prepare Common Network Parameters and Transport Zones Prepare a tunnel IP address pool, define common host uplink and tunnel parameters, and associate clusters with transport zones according to VLAN or Overlay workload requirements. These configurations determine the hosts' basic network parameters and the scope of workload network transport, respectively.
Apply Configurations to Hosts Common parameters must be combined with each host's physical NICs to forward network traffic. Use Connect Hosts and Check Synchronization Status to configure uplink mappings, select common or override parameters, and connect hosts to Fabric.
Prepare Edge Resources as Needed For Tier-0 connectivity or centralized network services, organize an edge cluster from hosts already connected to the site's Fabric to provide resources for the relevant gateways and services.

When expanding an existing site, first check whether its common configuration and transport zones are suitable. Then add associations for new clusters and connect new hosts. Use the relevant maintenance procedures to change existing resources.

Connections Between Sites

To connect networks at different sites, prepare each site's local Fabric, set up a DCI Gateway at each end, and create a site interconnect. For the resource relationships and configuration process, see Site Interconnect.

A site interconnect provides the infrastructure for inter-site transport. To connect workload gateways at the two sites, also follow Create a Tier-1 Peering Connection and configure the relevant workload routes.

Prepare for Fabric Configuration

Determine the site scope, physical uplinks, tunnel addresses, and host configuration approach.

Compute Resources and Site Scope

  • You have opened the ZNS management interface. The target compute manager is connected, and the required clusters and hosts have been discovered.
  • Define sites by physical location and failure domain. Clusters to be added to the same site must be at the same physical site, with connectivity over the site's underlay/local network. Sharing a compute manager or a ZSphere data center does not by itself establish that these conditions are met.
  • Check the clusters' existing site membership. When creating a site, the candidate list excludes clusters that already belong to other sites.
Option Description
Physical NICs Prepare dedicated, available uplink NICs for ZNS networks. Check the NIC names on each host and their connections to physical switch ports.
Logical Uplinks Determine the names and number of logical members, and map them to physical NICs when connecting hosts. Each host requires at least one valid mapping, with a one-to-one correspondence between physical NICs and logical members on that host.
MTU and Bonding Determine the uplink MTU and Bond algorithm, and prepare matching physical link configurations. Available algorithms are active-backup, balance-slb, and balance-tcp.
Datapath Datapath determines the data plane of the host's virtual switch. The interface provides kernel and dpdk. The current ZSphere integration uses kernel and does not support dpdk. The site's common configuration provides the base values, which host shared or dedicated configurations can override. Regardless of the configuration source, hosts running ZSphere VMs must use kernel.
VTEP Addresses Prepare an IPv4 address pool and Tunnel VLAN for host tunnel endpoints. Ensure that the addresses are available and that the physical network can carry the tunnel traffic. Plan tunnel addresses separately from workload VM addresses.

An initial site Fabric configuration requires a VTEP IP address pool. Use Prepare a VTEP IP Address Pool to create or check a pool, then complete Configure Site Fabric Common Parameters for the First Time.

Transport Zones and Configuration Reuse

Determine whether workloads use VLAN, Overlay, or both, and check the site's existing default and custom transport zones. Associate target clusters with the required zones. Hosts must also be connected to Fabric.

Hosts that use the same parameters can inherit the common configuration. Prepare a host shared configuration to reuse another set of override parameters. For a host that requires its own parameters, select a dedicated configuration when connecting the host or editing its configuration.

If hosts already carry workloads, assess the impact on those hosts and workload networks before changing Uplink, MTU, Datapath, or Tunnel VLAN settings, and schedule the changes accordingly.

Resources Required by Workloads

For Tier-0 connectivity, select hosts already connected to the site's Fabric for an edge cluster. To connect different sites, separately plan dedicated DCI NICs, carrier subnets, member fixed IP addresses, and VTEP VIPs at both ends. For the requirements, see Set Up a DCI Gateway.

Create a Site and Associate Clusters

Create a site in ZNS and add discovered compute clusters to it.

Before you begin

  • You have completed Prepare for Fabric Configuration.
  • The target clusters have been discovered through a compute manager and do not belong to other sites.
  • The clusters to associate are at the same physical site and in the same failure domain, with connectivity over the site's underlay/local network.

Procedure

  1. In ZNS, choose System > Fabric > Sites and check whether a suitable site already exists.
  2. If a new site is required, click Create Site, and enter a Name and an optional Description.

    The name must not exceed 64 characters. If a suitable site already exists, open its details and add the required clusters under Member Clusters.

  3. Under Cluster, select the compute clusters to include in the site. Check their names and compute managers.
  4. Click OK.
  5. Return to the site list and open the target site. Under Member Clusters, check the associated clusters and their compute managers.

Results

The site is created, and the target compute clusters belong to it.

Prepare a VTEP IP Address Pool

Create or reuse an IPv4 address pool for Fabric to allocate host tunnel endpoint addresses within a site.

Before you begin

You have planned the IPv4 address range for the host tunnel network and checked that the addresses are not used for other purposes.

Procedure

  1. In ZNS, choose Network > IP Management > IP Address Pool and check whether a pool matching the plan already exists.
  2. Optional: If no suitable pool exists, create one.
    1. Click Create IP Address Pool.
    2. Enter a Name, select a Network Segment Mode, and configure the address range.
      Option Description
      Name Enter 1–255 characters without spaces.
      CIDR Enter an IPv4 network address and prefix, such as 192.0.2.0/24.
      IP Range Enter the Start IP, End IP, and Subnet Mask. The start and end addresses must be in the same subnet, and the end address must not be less than the start address. The allocatable range must not include the network or broadcast address.
    3. Check the address range and click OK.
  3. In the address pool list, check the name and CIDR or start and end addresses of the pool to use.

Results

An IP address pool matching the tunnel address plan is ready for selection in Configure Site Fabric Common Parameters for the First Time.

Configure Site Fabric Common Parameters for the First Time

Set the site's logical uplink, Datapath, and VTEP tunnel parameters for the first time, before connecting hosts.

Before you begin

  • The site is created, you have checked its member clusters, and no hosts are connected to its Fabric.
  • You have prepared the address pool described in Prepare a VTEP IP Address Pool and planned the hosts' physical uplinks.

About this task

This task prepares the initial common configuration for connecting hosts. To change an existing common configuration, follow Edit Fabric Common Parameters in Adjust Fabric Resource Configurations, first checking the referencing hosts and the impact of the changes. The VTEP address pool and Tunnel VLAN cannot be edited while hosts are connected.

Procedure

  1. In ZNS, choose System > Fabric > Sites and click the target site name.
  2. Open Fabric Configuration > Common Configuration, check the current parameters, and click Edit Common Configuration.
  3. Configure the common parameters.
    Option Description
    Name Displays the site's Fabric configuration name.
    Description Enter configuration information as needed.
    Datapath For the ZSphere integration, select kernel as the forwarding mode for hosts that inherit the common configuration.
    Uplink Group Name Displays the uplink group name.
    Uplink MTU Enter an integer from 576 to 9216 that matches the planned physical link MTU.
    Bond Algorithm Select active-backup, balance-slb, or balance-tcp.
    Uplink Members Keep at least one logical member. Member names must be unique. Map the members to physical NICs when connecting hosts.
    IP Address Pool Select the pool that allocates host tunnel endpoint addresses. A pool is required for the initial configuration.
    Tunnel VLAN After selecting an address pool, enter an integer from 0 to 4094.
  4. Check the configuration and click OK.
  5. Return to Common Configuration and check that the uplink and VTEP parameters match the plan.

Results

The site has a common uplink and tunnel configuration that hosts can inherit.

Configure Transport Zones for Clusters

Prepare VLAN or Overlay transport zones and associate the site's compute clusters with the zones they need to use.

Before you begin

The target clusters belong to the current site, and you have determined which VLAN or Overlay workload networks they need to carry.

About this task

A transport zone defines the scope of workload network transport. After a cluster joins a site, it must also be associated with the required transport zones. Hosts can use the corresponding networks after connecting to Fabric.

Procedure

  1. In ZNS, choose System > Fabric > Sites and click the target site name.
  2. Open Transport Zones and check the existing zones.

    Check each zone's name, traffic type, default or custom designation, and associated cluster count. Use an existing zone if it matches the plan.

  3. Optional: If no suitable zone exists, create a transport zone.
    1. Click Create Transport Zone, enter a Name and an optional Description, and set Type to VLAN or Overlay.
    2. Check the Site, click OK, and return to the list to check the creation result.
  4. Optional: If the target clusters are not yet associated, add their transport zone associations.
    1. From the target transport zone's Actions, choose Add Cluster.
    2. Select the clusters to associate, check their names and compute managers, and click OK.

    Candidate clusters are from the current site. To carry multiple types of workload networks, associate the required transport zones as planned.

Results

Check the target zone's associated clusters. Confirm that all selected clusters are associated with the zone, and check the associated cluster count.

Create a Host Shared Configuration

Create a reusable Datapath, uplink, and tunnel override configuration for multiple hosts within the site.

Before you begin

You have completed Configure Site Fabric Common Parameters for the First Time and determined which override parameters to reuse.

About this task

A host shared configuration can be referenced by hosts within the site. Physical NIC mappings are still configured separately for each host.

Procedure

  1. In ZNS, choose System > Fabric > Sites and click the target site name.
  2. Open Fabric Configuration > Shared Configuration and click Create Host Shared Configuration.
  3. Enter a Name and an optional Description. Check the parameters populated from the site's common configuration, and set the values to override.
    Option Description
    Datapath For ZSphere hosts, select kernel.
    Uplink Group Name Uses the uplink group name from the site's common configuration.
    Uplink MTU Enter an integer from 576 to 9216.
    Bond Algorithm Select active-backup, balance-slb, or balance-tcp.
    Tunnel VLAN Enter an integer from 0 to 4094 as needed.
  4. Check the override parameters and click OK. Return to the shared configuration list to check the result.

Results

The host shared configuration is created and can be referenced by hosts within the site.

What to do next

To apply this configuration, follow Connect Hosts and Check Synchronization Status or Edit Host Configurations and Resynchronize, set Configuration Inheritance to Host Shared Configuration, and select this configuration.

Connect Hosts and Check Synchronization Status

Connect the site's hosts to Fabric, set physical NIC mappings and configuration sources, and check configuration synchronization results.

Before you begin

Procedure

  1. In ZNS, choose System > Fabric > Sites and click the target site name.
  2. Open Host Connections and click Connect Hosts.
  3. Under Hosts, select the target hosts and check their membership. Candidates are hosts within the site that are not yet connected to Fabric.
  4. Select the Configuration Method and enter uplink mappings.
    • Use Batch Configuration when multiple hosts reuse the same configuration. Check the NICs actually available on each host.
    • Use Configure by Host to set mappings and a configuration source separately for each host.
    • Under Uplink Mapping, map physical NICs to the logical Uplink members defined in the common configuration. Each host requires at least one valid mapping, with a one-to-one correspondence between NICs and logical members on that host. Not all logical members need to be mapped.
  5. Select a Configuration Inheritance option.
    Configuration Source Action
    Inherit Common Configuration Select this option when the host uses the site's common network parameters.
    Host Shared Configuration Select an existing shared configuration from the site when multiple hosts need to reuse the same override parameters.
    Dedicated Configuration Select this option when the host requires its own override parameters, and configure Datapath, Uplink MTU, the Bond algorithm, and Tunnel VLAN. For ZSphere hosts, select kernel for Datapath. MTU must be an integer from 576 to 9216, and Tunnel VLAN must be an integer from 0 to 4094.
  6. Check the selected hosts, NIC mappings, and configuration sources, and click OK.
  7. Return to the Host Connections list and check each target host's connection status, Datapath, configuration source, and Synchronization Status.

    For hosts running ZSphere VMs, confirm that the effective Datapath is kernel. When using a shared or dedicated configuration, check the actual value after overrides.

    Wait for Synchronization Status to become In Sync. Provisioning indicates that processing is still in progress. If Out of Sync is displayed, follow Edit Host Configurations and Resynchronize to check the configuration and host network, then resynchronize. Check host connectivity and configuration synchronization separately.

Results

The target hosts are connected to the site's Fabric. Physical uplink mappings and configuration sources are defined, and the network configuration is synchronized.

What to do next

If these hosts need to carry Tier-0 gateways or centralized network services, see Create an Edge Cluster.

Create an Edge Cluster

Organize hosts already connected to the site's Fabric to provide edge resources for Tier-0 gateways and centralized network services.

Before you begin

You have completed Connect Hosts and Check Synchronization Status and confirmed that the network configuration of the planned member hosts is synchronized.

Procedure

  1. In ZNS, choose System > Fabric > Sites and click the target site name.
  2. Open Edge Clusters and click Create Edge Cluster.
  3. Enter a Name and an optional Description, and select members under Hosts.

    Candidates are hosts within the site that are already connected to Fabric.

  4. Check the site and members, and click OK.

Results

Return to the edge cluster list and check the host count and site membership. Confirm that the configuration state is Deployed before using the cluster for a Tier-0 gateway.

Adjust Fabric Resource Configurations

Change an existing site's common parameters, host shared configurations, transport zone associations, or edge cluster members.

In ZNS, choose System > Fabric > Sites and click the target site name. Open the relevant configuration tab and perform the required changes below.

Edit Fabric Common Parameters

Use this section to change an existing common configuration. Changes to common network parameters affect hosts that use the configuration. Changes to Uplink, MTU, or Tunnel VLAN may cause link switching, packet loss, or workload network interruption. Confirm the scope of the changes before submitting them.

The VTEP address pool and Tunnel VLAN cannot be edited while hosts are connected. To replace or clear them, first complete Disconnect Hosts and wait until all hosts in the site are disconnected before making changes.

  1. Open Fabric Configuration > Common Configuration and click Edit Common Configuration.
  2. Change the common parameters according to the change plan.

    Option Description
    Name Displays the site's Fabric configuration name.
    Description Enter configuration information as needed.
    Datapath For the ZSphere integration, select kernel as the forwarding mode for hosts that inherit the common configuration.
    Uplink Group Name Displays the uplink group name.
    Uplink MTU Enter an integer from 576 to 9216 that matches the planned physical link MTU.
    Bond Algorithm Select active-backup, balance-slb, or balance-tcp.
    Uplink Members Keep at least one logical member. Member names must be unique. Map the members to physical NICs when connecting hosts.
    IP Address Pool Select the pool that allocates host tunnel endpoint addresses.
    Tunnel VLAN After selecting an address pool, enter an integer from 0 to 4094.
  3. Check the configuration and impact scope, and click OK.
  4. Return to Common Configuration to check the parameters, and check configuration synchronization results for existing hosts under Host Connections. To resynchronize, see Edit Host Configurations and Resynchronize.

If you disconnected hosts to replace the VTEP configuration, reconnect them after the changes by following Connect Hosts and Check Synchronization Status.

Edit a Host Shared Configuration

Changing Datapath, Uplink, or Tunnel VLAN in a shared configuration changes the network configuration of hosts that reference it and may affect workload connectivity. First check Referenced Hosts and the affected hosts, and schedule the changes accordingly.

  1. Open Fabric Configuration > Shared Configuration and choose Edit for the target configuration.
  2. Change the name, description, or override parameters as needed.

    Option Description
    Datapath For ZSphere hosts, select kernel.
    Uplink Group Name Uses the uplink group name from the site's common configuration.
    Uplink MTU Enter an integer from 576 to 9216.
    Bond Algorithm Select active-backup, balance-slb, or balance-tcp.
    Tunnel VLAN Enter an integer from 0 to 4094 as needed.
  3. Check the scope of the changes and click OK.
  4. Return to Host Connections and check the synchronization status of hosts that reference this configuration. To resynchronize, see Edit Host Configurations and Resynchronize.

Edit Transport Zone Information

  1. Open Transport Zones and choose Edit for the target zone.
  2. Change the Name or Description, click OK, and return to the list to check the result.

Add Transport Zone Associations

  1. Open Transport Zones. From the target zone's Actions, choose Add Cluster.
  2. Select the clusters to associate. Candidates are from the current site. Check the cluster names and compute managers.
  3. Click OK, confirm that all selected clusters are associated with the target zone, and check the associated cluster count.

To carry multiple types of workload networks, associate the required transport zones as planned.

Remove Cluster Associations from a Transport Zone

Removing a cluster's last transport zone clears the transport zone configuration from the hosts in that cluster. The system rejects the operation if the cluster carries workloads. Handle affected workloads before removing the association.

  1. Open Transport Zones. From the target zone's Actions, choose Remove Cluster.
  2. Select the clusters whose associations you want to remove, check the objects, and click OK.
  3. Check the associations after the operation. Confirm that other required transport zone associations remain correct.

Adjust Edge Cluster Members and Information

Changing members changes the scope of edge resources available to carry traffic. If gateways or network services are already associated, first check the dependencies and workload impact.

  1. Open Edge Clusters and choose Edit for the target cluster.
  2. Change the name, description, or member hosts. Members must be hosts within the site that are already connected to Fabric.
  3. Check the members and click OK.
  4. After the changes, check the host count, configuration state, and status of the relevant gateways and services.

Edit Host Configurations and Resynchronize

Change NIC mappings or configuration sources for connected hosts, and resynchronize the network configuration as needed.

Before you begin

  • The target host is connected to the site's Fabric and is not being disconnected.
  • You have checked the current mappings, configuration source, and parameters to change.

About this task

Changing uplink mappings, Datapath, MTU, Bond, or Tunnel VLAN changes the host network and may affect the workload traffic it carries. Confirm the affected workloads and schedule the changes before submitting them.

Procedure

  1. In ZNS, choose System > Fabric > Sites and click the target site name.
  2. Open Host Connections. From the target host's Actions, choose Edit Host Configuration.
  3. Change the mappings between physical NICs and logical Uplinks, or adjust Configuration Inheritance.

    Each host requires at least one valid NIC mapping, with a one-to-one correspondence between physical NICs and logical members. Select a configuration source based on the host's network requirements:

    • Inherit Common Configuration: Use the site's common network parameters.
    • Host Shared Configuration: Select an existing shared configuration from the site to reuse the same override parameters.
    • Dedicated Configuration: Set Datapath, Uplink MTU, the Bond algorithm, and Tunnel VLAN for this host. For ZSphere hosts, select kernel for Datapath. MTU must be an integer from 576 to 9216, and Tunnel VLAN must be an integer from 0 to 4094.

    To change the site's common or shared values, see Edit Fabric Common Parameters and Edit a Host Shared Configuration, respectively.

  4. Check the changes and click OK. Return to the list to view synchronization status. For hosts running ZSphere VMs, confirm that the effective Datapath is kernel.
  5. To apply the configuration again, choose Resynchronize for the target host and wait for Synchronization Status to become In Sync.

    Only connected hosts whose synchronization status is In Sync or Out of Sync can be resynchronized. Wait for the current operation to finish if a host is Provisioning or being disconnected.

Results

The host uses the updated mappings and configuration source, and the configuration synchronization result has been checked.

What to do next

If Out of Sync is still displayed, check host connectivity, physical NICs, common or override configurations, and the tunnel network. Correct the issues and resynchronize.

Disconnect Hosts

Remove hosts' connections to the site's Fabric to prepare for their removal or reconfiguration.

Before you begin

  • The target hosts are connected to Fabric and are not being disconnected.
  • You have handled workloads on the target hosts that depend on the current network and checked resource relationships such as edge clusters and DCI Gateways.

About this task

Disconnecting hosts removes them from the current Fabric network transport scope and affects workloads that depend on that network. This operation removes Fabric connections. Compute host resources in ZSphere are still managed through their own lifecycle.

Procedure

  1. In ZNS, choose System > Fabric > Sites and click the target site name.
  2. Open Host Connections and choose Disconnect Hosts for the target host. For a batch operation, first select the target hosts, then start the operation from Bulk Action.
  3. Check the host names in the confirmation window and confirm disconnection.
  4. Return to the list and wait for disconnection to complete. Check that the target hosts are no longer connected members of the current Fabric.

Results

The target hosts' Fabric connections are removed.

What to do next

To change the VTEP address pool or Tunnel VLAN, wait until all hosts in the site are disconnected, follow Edit Fabric Common Parameters, and then reconnect the hosts.

Clean Up Unused Fabric Resources

After removing references, delete unused IP address pools, host shared configurations, custom transport zones, or edge clusters as needed.

In ZNS, perform the operation for the resource you need to clean up. For site resources, choose System > Fabric > Sites and open the target site. Manage IP address pools under Network > IP Management > IP Address Pool.

Delete an IP Address Pool

Before deleting a pool, confirm that it is no longer used by a site's VTEP configuration. Remove or replace existing references first if the pool is still in use. For the conditions and procedure for replacing a site's VTEP configuration, see Edit Fabric Common Parameters.

  1. Choose Network > IP Management > IP Address Pool, find the target pool in the list, and choose Delete from Actions.
  2. Check the pool name in the confirmation window and confirm deletion. Return to the list to check the result.

Delete a Host Shared Configuration

A configuration cannot be deleted while hosts reference it. First follow Edit Host Configurations and Resynchronize to switch the referencing hosts to other configuration sources, then confirm that Referenced Hosts is 0. The deleted configuration is no longer available and must be recreated to restore it.

  1. Open the target site, open Fabric Configuration > Shared Configuration, and choose Delete for the target shared configuration.
  2. Check the object in the confirmation window and confirm deletion. Return to the list to check the result.

Delete a Custom Transport Zone

The target must be a user-created custom transport zone that is not referenced by hosts or segments. Default transport zones cannot be deleted. To remove cluster associations first, follow Remove Cluster Associations from a Transport Zone.

  1. Open the target site, open Transport Zones, and choose Delete for the target zone.
  2. Check the zone name in the confirmation window and confirm deletion. Return to the list to check the result.

Delete an Edge Cluster

Deletion may interrupt gateways and network services that depend on the cluster and cannot be undone. Handle the resource dependencies before deleting the cluster. To restore it, recreate the cluster and restore the relevant configurations.

  1. Open the target site, open Edge Clusters, and choose Delete for the target cluster.
  2. Check the cluster name in the confirmation window and confirm deletion. Return to the list to check the result.

Manage Sites and Member Clusters

Maintain site information, add or remove member clusters, and delete sites after clearing dependencies.

In ZNS, choose System > Fabric > Sites and click the target site name.

Edit Site Information

  1. Choose Edit from Actions in the site list or More actions on the details page.
  2. Change the Name and Description, check the changes, and click OK.

Add Member Clusters

The clusters to add must be at the same physical site and in the same failure domain, with connectivity over the site's underlay/local network. Sharing a compute manager or data center does not establish that these conditions are met.

  1. Open Member Clusters and click Add Cluster.
  2. Select the target clusters, check their names and compute managers, and click OK.
  3. Check the result in the member list. Then follow Add Transport Zone Associations to associate the new clusters with the required zones, and connect the relevant hosts.

Remove Member Clusters

Removing a cluster only removes its site mapping; it does not delete the compute cluster. The system rejects the operation if associated resources exist. First handle the cluster hosts' Fabric connections and other associated resources.

  1. Under Member Clusters, choose Remove from Site for the target cluster.
  2. Check the object in the confirmation window and confirm the operation. Return to the member list to check the result.

Delete a Site

Before deleting a site, handle dependent workloads and clean up the relevant Tier-1 peering connections, cross-site deployment relationships for segments, site interconnects, DCI Gateway, and edge clusters. Then complete Disconnect Hosts, follow Remove Cluster Associations from a Transport Zone, remove member clusters from the site, and clean up unused custom transport zones. The system automatically cleans up the site's internal configurations and unused default transport zones.

  1. Remove the relationships in the order above, and confirm that the member clusters have been removed from the site.
  2. Return to the site list and choose Delete for the target site.
  3. Check the site name in the confirmation window and confirm deletion. Check the list after the operation.

Site Interconnect

Prepare inter-site transport resources, connect two sites, and provide the infrastructure for subsequent workload gateway connectivity.

To establish a network between different sites, set up a DCI Gateway at each end, then create a site interconnect. A DCI Gateway uses dedicated NICs, fixed IP addresses, and a VTEP VIP on the site's member hosts to carry inter-site traffic. A site interconnect connects two sites and maintains the VNI range for inter-site encapsulation.

Resource Relationships and Configuration Order

  1. Organize sites and compute resources at both ends, and check the host network and inter-site physical transport plans.
  2. Complete Set Up a DCI Gateway at each end, and check member hosts, VIPs, carrier subnets, and physical next hops.
  3. Follow Create and Manage Site Interconnects and check both gateways and the interconnect configuration state.
  4. For workload gateway connectivity, continue with Create a Tier-1 Peering Connection and configure the relevant workload networks, then verify actual connectivity.

A Tier-1 peering connection within the same site does not require a site interconnect. A Tier-1 peering connection between sites requires an available site interconnect between those sites. Creating the interconnect establishes the transport relationship; workload subnets still require the corresponding gateway and routing configurations.

Addressing and Encapsulation Scope

The site Fabric VTEP address pool provides addresses for host tunnel endpoints within the site. A DCI Gateway uses a separately configured dedicated carrier subnet, member fixed IP addresses, and VTEP VIP. Plan each configuration according to the physical network.

Site interconnects use VXLAN encapsulation, with the VNI range allocating inter-site encapsulation identifiers. The Geneve network identifiers for Overlay segments within a site are configured as described in the workload segment topics.

Edge clusters provide resources for local network egress, such as Tier-0 gateways. DCI Gateways provide resources for site interconnects.

Set Up a DCI Gateway

Configure the site's inter-site transport hosts, dedicated NICs, member addresses, and VTEP VIP.

Before you begin

The site is created and does not yet have a DCI Gateway. You have prepared the following resources according to the inter-site transport plan.

  • Select 1–2 member hosts from the site. With a single member, only that host can carry traffic, so assess the single-point risk.
  • Prepare dedicated DCI NICs and a reachable physical network for the members, and determine whether to use NoVLAN or VLAN transport.
  • Prepare a dedicated IPv4 carrier subnet, a fixed IP address for each member, and the gateway's VTEP VIP. The subnet must not include any member host's management IP address.
  • Member fixed IP addresses, the VTEP VIP, and the optional physical next hop must be usable addresses within the carrier subnet. They must not be network or broadcast addresses, and must be distinct from one another.
  • If the peer VTEP VIP is outside this site's carrier subnet, prepare a physical next hop that can reach the peer.

Procedure

  1. In ZNS, choose System > Fabric > Sites and click the target site name.
  2. Open DCI Gateway and click Set DCI Gateway.
  3. Enter the gateway configuration.

    The member selection order determines the HA priority order. The first member is the preferred forwarding node. Select members in the planned order.

    Option Description
    Member Hosts Select 1–2 hosts from the site in HA priority order.
    NIC Configuration Select Use Same NIC or Configure per Host. The former selects a VTEP NIC with the same name for all members; the latter allows a separate selection for each host.
    VTEP NIC Select a dedicated NIC for DCI traffic.
    VTEP VIP Enter the IPv4 virtual address used by this gateway.
    Carrier Network Mode Select NoVLAN or VLAN to match the physical network.
    Carrier VLAN ID In VLAN mode, enter an integer from 1 to 4094. All members of the same gateway use this VLAN.
    Carrier CIDR Enter an IPv4 network address with a prefix length from 1 to 30, such as 192.0.2.0/24.
    Fixed IP Enter each member's fixed address within the carrier subnet.
    Physical Next Hop Enter this address if the peer VTEP VIP is outside the current carrier subnet. It must also be a usable address within the local carrier subnet.
  4. Check the addresses and member order, click OK, and return to the DCI Gateway tab to wait for configuration to complete.

Results

Check the local gateway's carrier configuration and VIP status.

  • Check Gateway Status. It is Active when the gateway is operating normally.
  • Confirm that Carrier Configuration is Carrier Configuration Ready, and check that member fixed IP addresses, VTEP NICs, the carrier VLAN, and subnet match the plan.
  • Check VIP Holder Host and each member's VIP Ownership to confirm actual VIP ownership. If the query fails, click Retry to query again.

What to do next

When both gateways are ready, you can create a site interconnect.

Create and Manage Site Interconnects

Connect two sites with prepared DCI Gateways, allocate an inter-site VNI range, and check and maintain the interconnect.

Before creation, complete Set Up a DCI Gateway at both sites, and check the gateways and physical transport configurations. In ZNS, choose System > Fabric > Site Interconnect.

  1. Open Site Interconnect and check whether a suitable interconnect already exists. To add one, click Create DCI Link.
  2. Configure the interconnect parameters.
Option Description
Name Enter an interconnect name that identifies the sites at both ends.
Site A, Site B Select two different sites. Check the DCI carrier subnets, VTEP VIPs, physical next hops, and carrier VLANs displayed after selection.
Encapsulation Currently VXLAN.
VNI Start, VNI End Enter integers from 1 to 16777215. The end value must not be less than the start value. This range allocates Outer VNIs for the interconnect.
  1. Check the sites and VNI range, and click OK.
  2. Return to the interconnect list and check the two sites, encapsulation type, VNI range, and Configuration Status. Wait for orchestration to complete.
  1. Click the interconnect name and open Overview. Check the sites, both DCI Gateways, the configuration state, and VNI usage.
  2. Open VNI Allocations and check allocated Outer VNIs by allocation type and associated resource.
  3. At each site's DCI Gateway, check Peer Carrier Reachability and use the returned results to check the inter-site transport path. An unknown status does not establish that the peer is reachable.

System Transit in VNI allocations represents internal Transit allocations that are not yet associated with a valid Tier-1 peering connection. It does not by itself indicate a fault.

If the interconnect is abnormal, first check both gateways' carrier configurations, VIPs, VTEP NICs, and physical next hops, then check carrier network connectivity. For workload gateway connectivity, follow Create a Tier-1 Peering Connection and configure workload routes, then verify actual workload connectivity.

  1. From the target interconnect's Actions, choose Rename.
  2. Update the Name, click OK, and return to the list to check the result.

An interconnect cannot be deleted while it carries segments deployed across sites. First remove these segments' associations with the interconnect, and handle dependent inter-site workloads and gateway connections.

  1. Choose Delete for the target interconnect.
  2. Check the interconnect name in the confirmation window and confirm deletion. After the operation, check the list and former dependencies.

To delete the DCI Gateways at both ends, first confirm that all interconnects associated with each site have been removed, then follow Delete a Gateway.

Maintain a DCI Gateway

Change an existing DCI Gateway's members, carrier network, and address configuration, or delete the gateway after removing site interconnects.

In ZNS, choose System > Fabric > Sites and click the target site name. Open DCI Gateway, check the current configuration and carrier status, and perform the required operation.

Edit a Gateway

Changing the member order updates HA priorities and may switch active/standby roles and forwarding paths, causing brief packet loss or jitter in inter-site traffic. Schedule the operation during a low-traffic period. After submitting priority changes, check which host actually holds the VIP.

The carrier network mode and VLAN ID cannot be changed while site interconnects exist. To change them, first delete the associated site interconnects and adjust the physical network accordingly. Reconfiguring the transport path may affect inter-site connectivity.

If only one member host remains, the gateway can only be carried by that host. Assess the single-point risk.

  1. Click Edit and change the required member, NIC, or address parameters.

    Option Description
    Member Hosts Select 1–2 hosts from the site in HA priority order.
    NIC Configuration Select Use Same NIC or Configure per Host. The former selects a VTEP NIC with the same name for all members; the latter allows a separate selection for each host.
    VTEP NIC Select a dedicated NIC for DCI traffic.
    VTEP VIP Enter the IPv4 virtual address used by this gateway.
    Carrier Network Mode Select NoVLAN or VLAN to match the physical network.
    Carrier VLAN ID In VLAN mode, enter an integer from 1 to 4094. All members of the same gateway use this VLAN.
    Carrier CIDR Enter an IPv4 network address with a prefix length from 1 to 30, such as 192.0.2.0/24.
    Fixed IP Enter each member's fixed address within the carrier subnet.
    Physical Next Hop Enter this address if the peer VTEP VIP is outside the current carrier subnet. It must also be a usable address within the local carrier subnet.

    The carrier subnet must not include any member host's management IP address. Member fixed IP addresses, the VTEP VIP, and the optional physical next hop must be usable addresses within the carrier subnet. They must not be network or broadcast addresses, and must be distinct from one another.

  2. Check member priorities, address rules, and affected interconnect relationships. Select the risk confirmation checkbox and click OK.
  3. Return to the details page and check the following status information.

    • Check Gateway Status. It is Active when the gateway is operating normally.
    • Confirm that Carrier Configuration is Carrier Configuration Ready, and check that member fixed IP addresses, VTEP NICs, the carrier VLAN, and subnet match the plan.
    • Check VIP Holder Host and each member's VIP Ownership to confirm actual VIP ownership. If the query fails, click Retry to query again.
    • Check Peer Carrier Reachability. After both ends and the interconnect are ready, use the returned results to check the inter-site transport path. An unknown status does not establish that the peer is reachable.

Delete a Gateway

A DCI Gateway cannot be deleted while its site has site interconnects. First handle dependent workloads, then delete the associated site interconnects.

  1. On the site's DCI Gateway tab, click Delete.
  2. Check the object in the confirmation window and confirm deletion. After the operation, check that the site no longer has this gateway configured.