Environment
- Product: ZCF
- Component: ZCE-X
- Affected objects: Dual management nodes, OSD disks, Ceph, and ZCE-X storage pools
- Version: 5.2.115.5
- Trigger condition: An isolated OSD disk has bad sectors and must be replaced individually.
Symptoms
- An OSD in the storage environment is isolated.
- Low-level checks find bad sectors on the disk.
- Hot-swap the disk and keep data recovery and balancing safe.
Diagnosis
- Confirm that the environment is within scope and record versions, system architecture, operating system, deployment mode, and storage type.
- Confirm that the Ceph cluster is healthy.
- Run
xms-manage db show-replication-infoandxms-manage -sand confirm normal database, ES, and ETCD status. - Operate on only 1 OSD on 1 node at a time.
Cause
The target OSD is isolated and has bad sectors. Take it offline safely, hot-swap the disk, and use low-speed recovery to limit the impact on workloads.
Resolution
1. Prerequisites
- Risk level: Low
- Disable cloud platform high availability and back up the databases.
- Operate on only 1 OSD on 1 node at a time.
- Continuously monitor
ceph -sand avoid prolongedpeeringorremappedstates.
2. Procedure
- Check the cluster and cloud platform.
xms-manage db show-replication-info
xms-manage -s
watch -n 1 ceph -s
- Expected result: Database, ES, ETCD, and Ceph status are normal.
- Disable global high availability and back up both databases.
zstack-ctl dump_mysql --file-name zstack-db-backup-master
zstack-ctl dump_mysql --file-name zstack-db-backup-slave
- Expected result: High availability is disabled and backups are complete.
- Disable Data Recovery on the storage platform.
- Expected result: Recovery traffic stops.
- Change the OSD type and stop the OSD from the command line.
echo xstore3 > /var/lib/ceph/osd/ceph-{osd_id}/type
cat /var/lib/ceph/osd/ceph-{osd_id}/type
systemctl stop ceph-osd@{osd_id}
systemctl status ceph-osd@{osd_id}
- Expected result: The type is
xstore3, and the service is stopped and offline.
- Monitor
ceph -s. After confirming no persistentpeering, remove and delete the OSD from the storage platform.
- Expected result: The failed OSD is removed.
- Hot-swap the offline failed disk.
- Expected result: The new disk is detected.
- Add the new disk to the storage pool with the same read-cache configuration as the original environment.
- Expected result: The disk joins the pool.
- Enable data balancing. Set recovery QoS to low speed in the storage UI and enable Data Recovery.
- Expected result: Low-speed recovery begins.
- Enable global VM high availability.
- Expected result: Normal high-availability status is restored.
Verification
- Run
ceph -sand confirm cluster health. - Confirm that the new disk is detected and added to the pool.
- Confirm normal workload operation after high availability is restored.
Risks and rollback
- Risk: Removing an OSD in the UI before completing low-level processing may cause an abnormality.
- Risk: Prolonged
peeringorremappedstates may affect workloads. - Risk: Scale-in and recovery create rebalancing traffic, so keep recovery QoS low.
- Rollback: If a PG is stuck, identify it and run:
ceph -s
ceph pg dump | grep -E "peering|remapped"
ceph pg dump | grep {pg_id}
ceph osd down {osd_id}