Scenario
- Product:
ZCF - Components:
ZStack Cloud,ZStone - ZStack Cloud version:
4.8.x - ZStone version:
5.2.x - Operating system:
h84r - Deployment: Three-node hyperconverged cluster with dual management nodes
- Trigger: A management node has a RAID controller failure and must be reinstalled and restored as a management and storage node.
Symptoms
- One management node in a hyperconverged cluster has a RAID controller failure.
- The node provides management services and is associated with mon, OSD, and cache resources.
- The legacy node must be removed before it is reinstalled and managed again.
Assessment
- Confirm that the failed node requires system reinstallation.
- After reinstallation, verify that ZStack Cloud, ZStone, high availability, and storage roles are restored.
- Verify that platform and storage status are normal after the node rejoins the environment.
Cause
A RAID controller failure on a management node requires full reinstallation, role reconstruction, and dual-management reconstruction.
Resolution
- Preparation
- Risk level: Medium.
- Disable platform high availability and storage data recovery.
- Back up ZStack Cloud and ZStone databases.
- Remove resources associated with the failed node in the UI and storage platform.
- Remove legacy resources from the failed node.
- Disable global high availability and data recovery.
- Back up the databases:
zstack-ctl dump_mysql
mysqldump -uroot -p<database_password> zstone > /var/lib/zstack/mysql-backup/zstone-backup.sql
- Expected result: ZStack Cloud and storage databases are backed up.
- In the ZStack Cloud UI, remove the mon node and compute node that require changes.
- Expected result: The platform no longer references the failed node.
- In the storage platform, remove the corresponding OSDs and cache partitions, then delete the node. If the UI cannot delete the resources, use the following APIs:
DELETE /api/v1/block/osdDELETE /api/v1/block/host- Expected result: Storage records for the failed node are cleared.
- Purge down OSDs on the underlying system:
ceph osd --force purge osd.X
- Expected result: Residual OSD records are removed.
- Delete the abnormal license record from the database on a healthy node:
mysql -uroot -p<database_password> zstone
delete from LicenseAppIdVO where hostIp='<failed_node_management_ip>';
- Expected result: The legacy node license binding is removed.
- Reload the license in the UI, then back up the database again.
- Expected result: The environment is ready for reinstallation.
- Reinstall the failed node.
- Reinstall the operating system and configure networking.
- ISO:
ZStack-x86_64-DVD-4.8.18-h84r.iso br_bond0: <management_network_cidr>br_bond2: <storage_network_cidr>- Expected result: Baseline networking is restored.
- Configure server time and write it to the hardware clock.
- Expected result: Time synchronization is normal.
- Install Cloud management services and apply for a temporary license.
- Expected result: ZStack Cloud management functions are restored.
- Change the database password:
zstack-ctl change_mysql_password --root-password <current_database_root_password> --user-name root --new-password <new_database_root_password>
- Expected result: The database password matches the existing environment.
- Update
zstack.properties.
- Expected result: ZStack Cloud configuration points to the correct environment.
- Reinstall
ZStone 5.2.xon the failed node, with the configuration file containing only the failed-node address.
Important: Install storage before installing high availability on the healthy node; otherwise, the ZStone database might be overwritten.
- Expected result: ZStone services on the failed node are restored.
- Reconstruct dual management and high availability.
- On the surviving management node, install high availability:
tar zxvf ZStack-Multinode-HA-Suite.tar.gz
chmod +x zsha2 zstack-hamoo
./zsha2 sample-config > zs-install.config
Configure gateway, virtualIp, myIp, peerIp, dbRootPass, interface, and timeServer.
- Expected result: Dual-management HA configuration is ready.
- Rewrite ZStone configuration on the failed node to use the VIP.
- Expected result: Dual-management configuration is consistent.
- Restart
zstone-master,zstnmon,zstone-ui,temporal-history / frontend / matching / worker / web,postgresql-9.6.x,zstone-prometheus,zstone-alertmanager,zstone-pushgateway,thanos-query, andthanos-sidecar.
- Expected result: Management and monitoring services are restored.
- Restore management.
- Add the original node, cache disks, and data disks in the storage UI.
- Add OSDs and enable data recovery.
- Add the corresponding node, mon node, and compute node in ZStack Cloud.
- Re-enable high availability.
- Expected result: The failed node is managed again and dual management is restored.
Verification
- Verify ZStack Cloud and ZStone database recovery.
- Verify networking, time, licensing, and management services on the reinstalled node.
- Verify cache disks, data disks, OSDs, and mon nodes in the storage UI.
- Verify dual-management high availability.
Risks and rollback
- Risk: Incorrect sequencing during management-node reconstruction and storage-role reconstruction can affect ZStack Cloud and ZStone data consistency.
- Risk: Installing high availability before storage can overwrite the ZStone database.
- Risk level: Medium.
- Rebuilding the services has no rollback path. Resolve issues item by item based on the reported error; do not attempt a standard rollback.