Document navigation

Applicable Scenario

  • Product: ZCF
  • Component: ZStack Cloud
  • Versions: 4.8.x and 5.2.x
  • ZCE version: 5.2.x
  • Operating system: Kylin V10 SP3
  • Kernel: 4.19.90-52.15.v2207.ky10.x86_64
  • RAID controller: 9460-8i (SAS3508)
  • Trigger condition: OSDs are frequently isolated by ZCE following dummy io detection timeouts, and RAID-controller driver stability is suspected.

Symptoms

  • OSDs are frequently isolated after dummy io detection timeouts.
  • The issue is initially suspected to be related to hardware stability.
  • The server vendor recommends updating the RAID-controller driver first and observing the result.

Diagnostic Procedure

  1. Verify that the environment and workloads allow node-by-node maintenance.
  2. Check the megaraid_sas driver version before and after the upgrade.
  3. After each node restart, wait for the storage pool to return to a healthy state before proceeding to the next node.

Cause

This is not a direct platform software error. Frequent OSD dummy io timeouts, together with the vendor recommendation, indicate a possible RAID-controller driver stability issue. Upgrade megaraid_sas to validate and mitigate the issue.

Resolution

  1. Preparation
  • Risk level: low, but this is an underlying driver change and must be performed node by node.
  • Disable global high availability.
  • Migrate VMs away from the target node.
  • Back up the database and driver files.
  • Disable data recovery during maintenance.
  1. Procedure
  2. Disable global high availability and migrate VMs away from the target node.
  • Expected result: the target node can be safely taken out of service for maintenance.
  1. Back up the driver and initramfs:
   mkdir -p /root/raid_driver_bak/
   cp /lib/modules/4.19.90-52.15.v2207.ky10.x86_64/kernel/drivers/scsi/megaraid/megaraid_sas.ko /root/raid_driver_bak/megaraid_sas.ko.bak
   cp /boot/initramfs-4.19.90-52.15.v2207.ky10.x86_64.img /boot/initramfs-4.19.90-52.15.v2207.ky10.x86_64.img.bak
  • Expected result: a basis for quickly rolling back the driver is available.
  1. Upgrade the driver:
   rpm -Uvh kmod-megaraid_sas-07.726.02.00-1.ky10.x86_64.rpm
  • Expected result: the new driver is installed.
  1. Check the version after the upgrade:
   cat /sys/module/megaraid_sas/version
   modinfo megaraid_sas | grep -E "^version:"
   cat /sys/module/megaraid_sas/version
  • Expected result: the module version shows the target version.
  1. Disable data recovery on the storage side.
  • Expected result: automatic recovery does not increase risk during the driver-upgrade restart.
  1. If the node is a management node, switch management services first:
   zsha2 demote
   zsha2 stop-node
  • Do not perform this step for a non-management node.
  • Expected result: management services do not conflict with the node restart.
  1. Restart the host:
   sync&&sync&&sync&&reboot
  • Expected result: the new driver takes effect after startup.
  1. Check the driver version again after the node restarts.
  • Expected result: the newly loaded driver version is confirmed.
  1. Enable data recovery and wait for the storage pool to return to a healthy state.
  • Expected result: the cluster returns to a stable state.
  1. Repeat the preceding steps for the other nodes in sequence.
  2. Enable global high availability after all nodes have been updated.
  • Expected result: the driver upgrade is complete.

Verification

  • Verify that the megaraid_sas driver version is correct on every node.
  • Verify that the storage pool returns to a healthy state after each operation.
  • Verify that OSDs are no longer frequently isolated because of dummy io timeouts.
  • Verify that workloads and ZStack Cloud resources are operating normally.

Risks and Rollback

  • Risk: this underlying driver change can affect compatibility and workload continuity.
  • Risk: operating multiple nodes concurrently can cause storage errors and workload interruption.
  • Risk: data recovery must remain disabled during the restart.
  • Risk level: low; however, treat this as a sensitive underlying change.
  • Rollback:
  1. Replace the current driver with the backed-up .ko file:
     cp /root/raid_driver_bak/megaraid_sas.ko.bak /lib/modules/4.19.90-52.15.v2207.ky10.x86_64/kernel/drivers/scsi/megaraid/megaraid_sas.ko
  1. Rebuild module dependencies and the boot image:
     depmod -a
     dracut -f /boot/initramfs-4.19.90-52.15.v2207.ky10.x86_64.img 4.19.90-52.15.v2207.ky10.x86_64
     reboot
  1. After the restart, check:
     cat /sys/module/megaraid_sas/version
     rpm -qa | grep megaraid_sas